Troubleshooting guide – Parasound P 3 User Manual

Page 23

background image

TROUBLE

No power

P 3 will not turn on with

DC trigger voltage

Power but no sound

Distorted sound through

speakers.

Hum and/or buzz through

speakers

PROBABLE CAUSE

Power cord is disconnected

Voltage

selector switch is in the

wrong position

AC fuse is blown

DC trigger source wired with reverse

polarity or voltage too low

Volume control turned down

Bad connection to power amplifier

External Loop

jumpers are missing

P 3 is muted

Damaged speaker

Problem with the power amplifier or

source component

The P 3

Balance

is adjusted all the

way to the left or right

Ground loop from cable TV

Ground loop between the P 3 and

power amplifier

Ground loop within equipment rack

Other ground loop

REMEDY

Connect power cord

Make sure the

Voltage

selector switch is in the

correct position for your region

Replace fuse with one of the same value

Check polarity of the DC trigger source with

a voltmeter

Increase the volume control setting

Check the output connections

Replace

External Loop jumpers

Press

Mute

button or adjust the Volume knob

or remote buttons to unmute the P 3

Exchange the left and right speaker cables.

If the same speaker is distorted, the speaker is

damaged. If not, the problem may be with your

power amplifier or further up the signal path

Exchange the left and right P 3 output cables.

If distortion stays in the same channel, the

problem is after the preamplifier

Re-adjust with the

Balance

buttons

Move the ground switch on the power amplifier

to its lift position. Install a cable isolation device

such as the Xantech 634 Ground Breaker.

www.xantech.com

Move the ground switch on the power amplifier

to its lift position.

Install nylon shoulder washers on both sides of

the rack-mounted panels of all equipment to

prevent the P 3 from making any metal-to-metal

contact with the rack

Contact Parasound Technical Service

TROUBLESHOOTING GUIDE

20

Your Parasound P 3 Preamplifier requires no periodic maintenance and has no user-serviceable
parts inside. To avoid the risk of electric shock, do not remove the top cover. The P 3’s
exterior can easily be cleaned with a soft cloth pre-moistened only with a few drops of
water or glass cleaner.

Main Power Fuse

If this fuse blows, please contact Parasound Technical Service for further advice.