TROUBLESHOOTING:

FRYING SYSTEM:

Should there be a problem with your machine, the following checks should be done prior to calling an Authorized
Service Company. Make sure the machine is operated correctly and that the Computer or Digital Display (when
installed) is programmed accordingly.

Check these items before calling your Authorized Service Company

ITEM TO CHECK

HOW TO CHECK

Power to machine

Check main power to machine (When applicable.)

Hi-Limit reset

Press Hi-Limit reset button. Mounted on left side of element
pivot assembly

Power switch on

Power switch should be in the ON position.

Locate the problem in the chart below then follow the instructions in the above chart.

PROBLEM

ITEM TO CHECK

Machine will not run:

Power to machine (Where applicable.)

No lights on the front panel

Bad Transformer

Machine will not run:

Hi-Limit switch

Front panel lights are ON.

Bad probe, Temperature control

Machine will not maintain temp:
Is machine still running? YES

Bad probe

NO

Bad Hi Limit

Oil temp too hot or Machine runs constantly

Check Thermostat calibration (Where applicable.)
Call Authorized Service Company

FILTERING SYSTEM:

Check these items before calling your Authorized Service Company

PROBLEM

CHECK

Power to machine

Check main power to the machine

Circuit breaker

Check filter circuit breaker on side of filter handle

Motor overheat trip

Remove cap on the left side at the rear of filter and push red
button

Shortening return quick disconnect

Fitting should be tight and clean

Pick up tube

Steel nut should be tight on the filter Pick up screen
inside tube should be clear
Fitting at top of tube should be tight

Paper installation

Paper should be installed per directions in the manual

Pick up screen

Check the small screen in the end of the pick up tube (Inside
the large steel nut.) to make sure it is clear

Filter pump NOT running

Check power to machine
Check circuit breaker
Check motor overheat trip

Filter pump running

Check quick disconnect
Check pick up tube is attached correctly
Check paper installation
Check pick up screen installation