1.3.4 Ventilation and Fire Fighting System

1.3.4.1

Fire Fighting System - It is very important to install an adequate fire fighting system. The

sensing device that activates the fire fighting system should be located according to manufactures
recommendations to reduce false alarms.

1.3.4.2

Ventilation - The Pasta cooker must have proper ventilation to function safely and

properly. The ventilation system should be designed to allow for easy cleaning. Frequent cleaning
of the ventilation system and the cooker will reduce the chances of fire. Table 1-2 provides a list of
reference documents that provide guidance on ventilation and fire safety systems. This table may
not be complete and other nationally recognized standards may apply.

Table 1-1. Electrical Requirements For Pasta Perfect Cooker Models

Model

Voltage and

Number

Phase Arrangement

Line Current

PE14 with

220 VAC

23.0 Amps

Basket Lift

Single Phase (2 wires and a ground)

PE14 with

240 VAC

25.0 Amps

Basket Lift

Single Phase (2 wires and a ground)

PE14 without

200 VAC

27.8 Amps

Basket Lift

Single Phase (2 wires and a ground)

PE14 without

208 VAC

28.9 Amps

Basket Lift

Single Phase (2 wires and a ground)

PE14 without

220 VAC

23.0 Amps

Basket Lift

Single Phase (2 wires and a ground)

PE14 without

240 VAC

25.0 Amps

Basket Lift

Single Phase (2 wires and a ground)