Pitco Frialator Electric Pasta Cookers RSE14 User Manual
Page 13
![background image](/manuals/183264/13/background.png)
1-5
1.3.4 Ventilation and Fire Fighting System
1.3.4.1
Fire Fighting System - It is very important to install an adequate fire fighting system. The
sensing device that activates the fire fighting system should be located according to manufactures
recommendations to reduce false alarms.
1.3.4.2
Ventilation - The Pasta cooker must have proper ventilation to function safely and
properly. The ventilation system should be designed to allow for easy cleaning. Frequent cleaning
of the ventilation system and the cooker will reduce the chances of fire. Table 1-2 provides a list of
reference documents that provide guidance on ventilation and fire safety systems. This table may
not be complete and other nationally recognized standards may apply.
Table 1-1. Electrical Requirements For Pasta Perfect Cooker Models
Model
Voltage and
Number
Phase Arrangement
Line Current
PE14 with
220 VAC
23.0 Amps
Basket Lift
Single Phase (2 wires and a ground)
PE14 with
240 VAC
25.0 Amps
Basket Lift
Single Phase (2 wires and a ground)
PE14 without
200 VAC
27.8 Amps
Basket Lift
Single Phase (2 wires and a ground)
PE14 without
208 VAC
28.9 Amps
Basket Lift
Single Phase (2 wires and a ground)
PE14 without
220 VAC
23.0 Amps
Basket Lift
Single Phase (2 wires and a ground)
PE14 without
240 VAC
25.0 Amps
Basket Lift
Single Phase (2 wires and a ground)