Fault finding, Ref•19 – Peugeot 205 User Manual
Page 236

Windscreen/tailgate wipers inoperative, or
unsatisfactory in operation
Wipers fail to operate, or operate very slowly
Ⅵ
Ⅵ
Wiper blades stuck to screen, or linkage seized or binding
(“Weekly checks” and Chapter 12).
Ⅵ
Ⅵ
Blown fuse (Chapter 12).
Ⅵ
Ⅵ
Cable or cable connections loose, broken or disconnected
(Chapter 12).
Ⅵ
Ⅵ
Faulty relay (Chapter 12).
Ⅵ
Ⅵ
Faulty wiper motor (Chapter 12).
Wiper blades sweep over too large or too small an area of
the glass
Ⅵ
Ⅵ
Wiper arms incorrectly positioned on spindles (Chapter 12).
Ⅵ
Ⅵ
Excessive wear of wiper linkage (Chapter 12).
Ⅵ
Ⅵ
Wiper motor or linkage mountings loose or insecure (Chapter 12).
Wiper blades fail to clean the glass effectively
Ⅵ
Ⅵ
Wiper blade rubbers worn or perished (“Weekly checks” ).
Ⅵ
Ⅵ
Wiper arm tension springs broken, or arm pivots seized
(Chapter 12).
Ⅵ
Ⅵ
Insufficient windscreen washer additive to adequately remove
road film (“Weekly checks” ).
Windscreen/tailgate washers inoperative, or
unsatisfactory in operation
One or more washer jets inoperative
Ⅵ
Ⅵ
Blocked washer jet (Chapter 1).
Ⅵ
Ⅵ
Disconnected, kinked or restricted fluid hose (Chapter 12).
Ⅵ
Ⅵ
Insufficient fluid in washer reservoir (Chapter 1).
Washer pump fails to operate
Ⅵ
Ⅵ
Broken or disconnected wiring or connections (Chapter 12).
Ⅵ
Ⅵ
Blown fuse (Chapter 12).
Ⅵ
Ⅵ
Faulty washer switch (Chapter 12).
Ⅵ
Ⅵ
Faulty washer pump (Chapter 12).
Washer pump runs for some time before fluid is emitted
from jets
Ⅵ
Ⅵ
Faulty one-way valve in fluid supply hose (Chapter 12).
Electric windows inoperative, or unsatisfactory in
operation
Window glass will only move in one direction
Ⅵ
Ⅵ
Faulty switch (Chapter 12).
Window glass slow to move
Ⅵ
Ⅵ
Regulator seized or damaged, or in need of lubrication
(Chapter 11).
Ⅵ
Ⅵ
Door internal components or trim fouling regulator (Chapter 11).
Ⅵ
Ⅵ
Faulty motor (Chapter 11).
Window glass fails to move
Ⅵ
Ⅵ
Blown fuse (Chapter 12).
Ⅵ
Ⅵ
Faulty relay (Chapter 12).
Ⅵ
Ⅵ
Broken or disconnected wiring or connections (Chapter 12).
Ⅵ
Ⅵ
Faulty motor (Chapter 11).
Central locking system inoperative, or
unsatisfactory in operation
Complete system failure
Ⅵ
Ⅵ
Blown fuse (Chapter 12).
Ⅵ
Ⅵ
Faulty relay (Chapter 12).
Ⅵ
Ⅵ
Broken or disconnected wiring or connections (Chapter 12).
Ⅵ
Ⅵ
Faulty control unit (Chapter 11).
Latch locks but will not unlock, or unlocks but will not lock
Ⅵ
Ⅵ
Faulty master switch (Chapter 12).
Ⅵ
Ⅵ
Broken or disconnected latch operating rods or levers
(Chapter 11).
Ⅵ
Ⅵ
Faulty relay (Chapter 12).
Ⅵ
Ⅵ
Faulty control unit (Chapter 11).
One solenoid/motor fails to operate
Ⅵ
Ⅵ
Broken or disconnected wiring or connections (Chapter 12).
Ⅵ
Ⅵ
Faulty solenoid/motor (Chapter 11).
Ⅵ
Ⅵ
Broken, binding or disconnected latch operating rods or levers
(Chapter 11).
Ⅵ
Ⅵ
Fault in door latch (Chapter 11).
Fault finding
REF•19
REF