MAINTENANCE
Customer Responsibilities
Daily or
after
each
use
Before
each
use
●
●
●
●
Every
8
hours
Every
40
hours
Every
100
hours
Yearly
Every
160
hours
●
●
1
1- more frequent in dusty or humid conditions
Check Safety Valve
Drain Tank
Oil Leaks
Check Oil
Change Oil
Air Filter
NOTE: See "Operation" section for the location of controls.
Unit cycles automatically when power is on. When
performing maintenance, you may be exposed to voltage
sources, compressed air, or moving parts. Personal injuries can occur.
Before performing any maintenance or repair, disconnect power source
from the compressor and bleed off all air pressure.
To Check Safety Valve
If the safety valve
does not work
properly, over-pressurization may
occur, causing air tank rupture or
an explosion.
Unusual Noise and/or
Vibration
Drive Belt-Condition
Motor Pulley/Flywheel alignment
Air compressor pump intake
and exhaust valves
●
●
●
●
Head Bolts - Check the torques of the head bolts after the first five hours of operation.
To ensure efficient operation and longer life of the air compressor outfit, a
routine maintenance schedule should be prepared and followed. The above
routine maintenance schedule is geared to an outfit in a normal working
environment operating on a daily basis. If necessary, the schedule should be
modified to suit the conditions under which your compressor is used. The
modifications will depend upon the hours of operation and the working
environment. Compressor outfits in an extremely dirty and/or hostile
environment will require a greater frequency of all maintenance checks.
1.
Before starting compressor, pull
the ring on the safety valve to
make sure that the safety valve
operates freely. If the valve is
stuck or does not operate
smoothly, it must be replaced
with the same type of valve.