Auto restart control, Indication panel, Auto operation switch – Panasonic CS-E21CKE User Manual
Page 29
![background image](/manuals/182097/29/background.png)
8.1.14. Auto Restart Control
1. When the power supply is cut off during the operation of air conditioner, the compressor will re-operate within three to four
minutes (there are 10 patterns between 2 minutes 58 seconds and 3 minutes 52 seconds to be selected randomly) after power
supply resumes.
2. This type of control is not applicable during ON/OFF Timer setting.
8.1.15. Indication Panel
LED
POWER MONITOR
POWER
QUIET
TIMER
POWERFUL
ION
Color
Green
Green
Orange
Orange
Orange
Green
Light ON
Compressor ON
Operation ON
Quiet Mode ON
Timer Setting ON
Powerful Mode ON
Ion Mode ON
Light OFF
Compressor OFF
Operation OFF
Quiet Mode OFF
Timer Setting OFF Powerful Mode OFF
Ion Mode OFF
Note:
• If POWER LED is blinking, the possible operations of the unit are Hot Start, during Deice operation, operation mode
judgment, or delay ON timer sampling.
• If Timer LED is blinking, there is an abnormality operation occurs.
• If Ionizer, LED is blinking, there is an abnormality of Ionizer occurs.
Power Monitor LED Control Frequency
Lighting of 3 LED base on instructed running frequency from indoor unit to compressor at cool, dry & heating operation.
Position of LED
Cool, Dry
Instructed Hz No
0
Hz
35
35
Hz
59
Hz
59
Heat
Instructed Hz No
0
Hz
44
40
Hz
63
Hz
63
8.1.16. Auto Operation Switch
1. When the switch is pressed between 0 to 5 seconds, Auto Mode operation starts to function.
2. When the switch is pressed between 5 to 8 seconds, the unit is forced to operate in Cooling Mode.
3. When the switch is pressed between 8 to 11 seconds, the unit is forced to operate in Heating Mode.
4. When the switch is pressed between 11 to 16 seconds and together with the signal from remote control, the unit can be
changed to different controlling setting (4 type of transmission codes).
5. When the switch is pressed between 16 to 21 seconds, either “H14” error detection selection mode or the remote control signal
receiving sound can be cancelled or turned on.
29