Model 2160 rear panel

21

Model 2160 Series User Manual

1 • General information

Reset button

To restart the unit with the current startup configuration—Press for less than 1 second and release the Reset
button. The Model 2160 will restart with the current startup configuration.

To restart the unit with factory default configuration—Press the Reset button for 5 seconds until the Power
LED starts blinking. The unit will restart with factory default configuration.

To restart the unit in bootloader mode (to be used only by trained CopperLink technicians)—Start with the
unit powered off. Press and hold the Reset button while applying power to the unit. Release the Reset button
when the Power LED starts blinking so the unit will enter bootloader mode.

Ground terminal

The marked lug or terminal should be connected to the building protective earth bus.The func-
tion of protective earth does not serve the purpose of providing protection against electrical shock,
but instead enhances surge suppression on the lines for installations where suitable bonding facili-
ties exist.The connector type is M3 machine screw.