TROUBLESHOOTING

WARNING: Disconnect tool from air supply and/or remove battery
before performing any Service Procedure.

SYMPTOM PROBLEMS

SOLUTIONS

1. Air leak near top of

Loose screws.

Tighten screws.

tool or in trigger area.

Worn or damaged

Install Overhaul Kit.

o-rings or seals.

2. Tool does nothing or

Inadequate air supply.

Verify adequate air supply.

operates sluggishly.

Inadequate lubrication.

Rotate air inlet to 12:00 position

and add 5-6 drops of oil .

Worn or damaged

Install Overhaul Kit.

o-rings or seals.

3. Air leak near bottom

Loose screws.

Tighten screws.

of tool.

Worn or damaged

Install Overhaul Kit.

o-rings or bumper.

4. Tool jams frequently.

Incorrect fasteners.

Verify approved fasteners of
correct size.

Damaged fasteners.

Replace w/undamaged fasteners.

Magazine or nose

Tighten screws.

screws loose.
Magazine is dirty.

Clean magazine.

Driver is worn or damaged.

Install Driver Maintenance Kit.

5. Insufficient nails per Switch set to high position. Use normal setting to maximize

battery charge. efficiency of tool.

6. Compressor runs Quick connect valve open. Rotate quick connect valve to the

continuously and red 8:00 “closed” position.
LED flashes rapidly.

7. Compressor does not Automatic shutdown feature Turn compressor off and back on

run and red LED activated because tool was to reset controls.
flashes slowly. idle for two hours.

8. Compressor does not Battery voltage to low Recharge or replace battery.

run and red LED is on. “discharged”.

9. Other Contact a Porter-Cable

Service Facility.

16

901891 - 08-31-01.qxd 2/13/02 11:53 AM Page 16