RS232 Communications Protocol & Command Set

(continued)

Request Input Voltage Level
Transmit the input AC voltage status

Send to UPS:

?INPUTVOLTS

Response from UPS:

XXXVACIN

XXX is the input AC voltage represented
in ASCII.

Request Output Voltage Status
Transmit the output voltage state

Send to UPS:

?OUTPUTSTAT

Response from UPS:

XXXVACOUT

XXX is the output voltage represented
in ASCII.

If the UPS is not in AVR or BATTERY mode:
Response from UPS:

NORMAL

If the UPS is in AVR mode and boosting voltage by 13%
Response from UPS:

AVRBOOST1

If the UPS is in AVR mode and boosting voltage by 26%
Response from UPS:

AVRBOOST2

If the UPS is in AVR mode and bucking voltage by 11%
Response from UPS:

AVRBUCK1

If the UPS is in BATTERY mode
Response from UPS:

BATTERY

Request Load Level Status
Transmit the load level percentage.

Send to UPS:

?LOADSTAT

Response from UPS:

XX%LOAD

XX is the load percentage represented
in ASCII.

Request Battery Charge Level Status
Transmit the remaining battery charge percentage.

Send to UPS:

?BATTERYSTAT

Response from UPS:

XX%BATTERY

XX is the battery charge percentage
represented in ASCII.

Identify Equipment
Transmit the model number, firmware number and revision.

Send to UPS:

?ID

Response from UPS:

PANAMAX

M1500-UPS

FWPARTNUMBER

REVREVISION

List all Commands and Queries

Send to UPS:

HELP

Response from UPS:

MAIN_ON

MAIN_OFF

NCL_ON

NCL_OFF

BATTHRESH

BEEPON

BEEPOFF

RESTORE

?OUTLETSTAT

?INPUTVOLTS

?OUTPUTSTAT

?LOADSTAT

?BATTERYSTAT

?ID

HELP