Diagnostics, Battery features, Continued) – Panamax M1500-UPS User Manual

Page 13

background image

Diagnostics

UNSAFE VOLTAGE

LINE FAULT

POWER ON

AVR MODE

BATTERY MODE

BATTERY LEVEL

LOAD LEVEL

MAX

®

Home Cinema UPS

Pure Sine W

ave

Intelligent Critical Load Control

11

USA & Canada (800) 472-5555 • (707) 283-5900 • Fax (707) 283-5901

Battery Features

(continued)

Battery Replacement Procedure

2. Remove the two retaining screws of the
cable protection cover then remove the cover.

6. Slide a new battery pack into the unit.
Assemble the screws, cover, cable and front
panel in the reverse sequence of above steps.

7. Recharge the unit for 4-8 hours to ensure
the UPS performs expected runtime.

4. Remove the four retaining screws.

3. Disconnect the black and red cable.

1. Remove the right side front panel using
pull-out handles.

5. Pull the battery pack out from the unit.

Battery pullout tab handle

Power
On LED

On

On

On

On

Off

Off

On/Off

Off

On

Off

On/Off

Wiring
Fault LED

Off

Off

Off

Off

Off

Off

Off

Off

Off

Off

On

AVR LED

Off

Slow Flash

Rapid Flash

On

Off

Off

On/Off/Flash

Off

On/Off/Flash

Off

On/Off/Flash

Using
Battery LED

Off

Off

Off

Off

On

On

On/Off

On

Off

Off

On/Off

Circuit
Breaker

Set

Set

Set

Set

Set

Set

Set

Up

Set

Set

Set/Up

Audible
Alarm

Off

Off

Off

Off

Two Beeps

Rapid Beeps

Long Beep

Long Beep

None

Off

None

Condition

Normal

AVR- Max. boost 13% of input voltage for output regulation while input voltage is
from 8% to 15% under nominal.

AVR- Max. boost 26% of input voltage for output regulation while input voltage is
from 15% to 26% under nominal.

AVR- Max. buck 15% of input voltage for output regulation while input voltage is
from 8% to 26% over nominal.

Utility Failure- The UPS is providing battery power to the connected equipment.

Utility Failure- The UPS is providing battery power. Rapid beeps indicate the battery
will run out of charge within a few minutes.

Overload- Turn the UPS off and unplug at least one piece of equipment from the UPS.
Wait 5 seconds, reset the circuit breaker and restart the UPS.

Overload- Turn the UPS off and unplug at least one piece of equipment from the UPS.
Wait 5 seconds, reset the circuit breaker and restart the UPS.

Weak Battery- Recharge the battery for at least 8 hours. If Check Battery is illuminat-
ed, contact Panamax for battery replacement information.

Surge Protection Malfunction- Power surge has damaged the unit. Please contact
Panamax.

Electrical Wiring Fault- Indicates wiring problems such as a bad ground, missed
ground or reversed wiring within the AC outlet. User is advised to disconnect all
electrical equipment from the outlet and have the outlet checked by an electrician.