beautypg.com

Table 2: network uses static ip addresses, Port information – Pitney Bowes DM SERIES AW20905 User Manual

Page 6

background image

6

All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical
(including photocopying, recording, or by any information storage retrieval system), without the owner’s express written permission.

AW20905 Rev. A


Table 2: Network Uses Static IP Addresses

DM500 through DM1000

DM300c through DM450c

1. Press

the

Menu key on the meter

1. Press the Menu key

2. Choose

Set up 2.

Choose

Data Center Options

3. Choose

Phone/Network Set Up 3.

Choose

Network Settings

4. Choose

More Options (down arrow)

4. Choose Get IP

5. Choose

Network Settings 5.

Choose

Specify Address Manually

6. Choose

Mailing System Network Settings

6. Choose

IP Addr, press the Clear key and then

enter the value determined by your network
administrator. Press the enter key to accept

7. Choose

Get IP Address

7. Choose

Subnet, press the Clear key and then

enter the value determined by your network
administrator. Press the enter key to accept

8. Choose

Specify an IP Address

8. Choose

Gateway, press the Clear key and then

enter the value determined by your network
administrator. Press the enter key to accept

9. Choose

IP Address, press the Clear key and

then enter the value determined by your network
administrator. Press the Enter key to accept

9. Press

the

Enter key to save your changes

10. Choose Subnet Mask, press the Clear key and

then enter the value determined by your network
administrator. Press the Enter key to accept

10. Press the Home key to return to the Mail Run

Screen

11. Choose Default Gateway, press the Clear key

and then enter the value determined by your
network administrator. Press the Enter key to
accept

12. Choose Exit Set up

Port Information

DM Series™ Mailing Systems require opening Port 80 (HTTP) and Port 21 (FTP) for communications
to Pitney Bowes Servers. Port 80 is used to communicate XML formatted messages requesting services
from Pitney Bowes’ postal and services related Servers. Port 21 is used to transmit new software and
graphics to the meter.


Other ports are used, and must be opened, depending upon additional packages that may be used in
conjunction with the meter. This will be covered in separate documents available with the purchase of
these options from Pitney Bowes. Available add-on packages include:

• Business Manager – Business Manager Configuration White Paper
• DFWorks™ – Systems Configuration – Network Ports Configuration