beautypg.com

PVI Industries Tank Series User Manual

Maxim• packaged gas/oil water heater

background image

MAXIM• PACKAGED GAS/OIL WATER HEATER

NICKELSHIELD

®

NICKEL-PLATED STORAGE TANK

250 GALLON TANK SERIES

MODEL NUMBER

40-2.8 N 250A-PGO

54-3.8 N 250A-PGO

72-5.0 N 250A-PGO

GPH Recovery at 40° to 120° F

500

670

900

GPH Recovery at 40° to 140° F

400

540

720

Input

Btu/h

400,000 540,000 720,000

Input, gph #2 Fuel Oil

2.8

3.8

5.0

A

Cold Inlet - NPT

2

2

2

B

Hot Outlet - NPT

2

2

2

C

Drain - NPT

1

1

1

D

I - Beam Skids

3 X 45

3 X 45

3 X 45

F

Overall

Height

75 82 82

G

Flue Outlet Diameter

7

8

10

H

Gas

Inlet

1 1 1

Minimum Inlet Flow Gas Pressure

4.5" W.C.

4.5" W.C.

6.5" W.C.

Maximum Static Gas Pressure

14" W.C.

14" W.C.

14" W.C.

J

Oil

Inlet

1/2 1/2 1/2

Motor HP 120 V, 1Ø, 60 Hz.

1/3

1/3

1/2

Motor

Amps

8

8

10

L

Height to Outlet

65

73

73

M

Height to Inlet

28

36

36

N

Overall

Depth

83 83 83

P

Depth of Burner Housing

31

31

31

Approx. Shipping Weight - lbs

1520

1600

1710

Recoveries based on 83% thermal efficiency. ASHRAE 90.1 compliant.
Dimensions are in inches unless otherwise specified.
For standard and optional equipment, see form # PV 6679

Product is patented in the U.S., Canada, and Mexico.

PVI INDUSTRIES, LLC

FORT WORTH, TEXAS 76111

PV 6676 01/05

(800) 784-8326

• www.pvi.com

STANDARD ELECTRICAL REQUIREMENTS

VENTING REQUIREMENTS

CONTROL VOLTAGE: 120V, 1Ø, 60 HZ., 2 AMPS

MOTOR VOLTAGE: 120V, 1Ø, 60 HZ.

SEE ABOVE CHART FOR BLOWER MOTOR AMPS

-.02" TO -.06" W.C. (NEGATIVE PRESSURE).

THE ENTIRE VENT SYSTEM SHOULD NEVER BE SIZED BASED

UPON THE VENT CONNECTION DIAMETER EXCLUSIVELY.

FOR PROPER VENT SIZING, CONSULT THE NATIONAL FUEL

GAS CODE UNDER "FAN-ASSISTED".

1. Control Enclosure
2. ASME Temperature &
Pressure Relief Valve
3. 3” NPT Handhole
4. Door swing requires 18"
in front of the water heater

PVI RESERVES THE RIGHT TO CHANGE

THE DESIGN AND SPECIFICATION WITHOUT NOTICE