MAINTENANCE

To reduce the risk of injury, turn unit off

and disconnect it from power source before installing and

removing accessories, before adjusting or when making

repairs. An accidental start-up can cause injury.
KEEP MACHINE CLEAN

Periodically blow out all air passages with dry compressed

air. All plastic parts should be cleaned with a soft damp cloth.

NEVER use solvents to clean plastic parts. They could possibly

dissolve or otherwise damage the material.

Wear certified safety equipment for eye,

hearing and respiratory protection while using compressed air.
FAILURE TO START

Should your machine fail to start, check to make sure the

prongs on the cord plug are making good contact in the outlet.

Also, check for blown fuses or open circuit breakers in the line.
LUBRICATION & RUST PROTECTION
Apply household floor paste wax to the planer table, extension

table or other work surface weekly. Or use a commercially

available protective product designed for this purpose. Follow

the manufacturer’s instructions for use and safety.
BRUSH INSPECTION ANd REPLACEMENT

disconnect tool from power source.

Brush life varies. It depends on the load on the motor. Check

the brushes after the first 50 hours of use for a new machine

or after a new set of brushes has been installed. After the first

check, examine them after about 10 hours of use until such

time that replacement is necessary.
The brush holders, one of which is shown at (A) Fig. 27, are

located on the motor housing opposite each other. One of the

brushes, removed for inspection, is illustrated in Fig. 28. When

the carbon (B) on either brush is worn to 3/16 inch (4.7 mm) in

length or if either spring (C) or shunt wire is burned or damaged

in any way, replace both brushes. If the brushes are found

serviceable after removing, re-install them in the same position

as removed.

After brush maintenance is completed, the

cutterhead guard must be re-installed before starting the

planer.
LUBRICATION
The gears in the gear box and the feed roller bushings should

be lubricated periodically.

disconnect tool from power source.

1. Remove the screw (A) Fig. 29, and nut located on the other

end of screw. Remove the side cover (B) from the left side

of the planer.

2. Place a light coat of E.P. multi-purpose grease on the teeth

of the gears (C) Fig. 30, and a light coat of spray lubricant

on the chains (F). Replace the side cover.

3. Place the planer on its back and squirt oil on the feed roller

bushings (D) Fig. 31 at each end of the feed rollers (E).

4. Replace side cover.