SPECIFICATION FOR DOMESTIC WATER HEATERS

Power Combustion, Oil-Fired Water Heaters with Nickel-Plated Storage Tanks

(continued)


Safety Controls


As a minimum, the heater will be equipped with the following:
• electronic flame monitoring with pre-purge (140,000 to 399,000 Btu/h burners) or electronic flame safeguard

with pre-purge and flame status indicating lights (600,000 to 3,200,000 Btu/h burners)

• two

immersion operating thermostats

• an immersion temperature limiting device

an ASME- or AGA-rated temperature and pressure relief valve

and options as selected on form PV 6004

Warranty Summary


Storage tank:

_____ year (10 standard, 20 optional) Covers manufacturing or material defects,

leaks and /or the production of rusty water. Tank coverage will include

failure due to scale buildup for ____ full years (5 standard, 8 optional) and

____ prorated years (5 standard, 12 optional) with no provision or condition

for maintenance or inspections and no limitations on water chemistry.


Heat

exchanger

and combustion chamber:

5 year. Covers manufacturing or material defects, leaks, and/or the

production

of

rusty

water.


Burner and all heater parts:

1 year


The heater will have a _____ first year or ____ long-life service policy, which will cover replacement labor and freight

costs under certain conditions. Initiation and /or continuation of warranty coverage will not be dependent upon annual
inspections, regular replacement of anode rods, or water chemistry. Complete copies of all warranties and service
policies, including all exclusions and conditions, will be presented to the owner as part of the submittal package. These
summaries are not warranties. Consult warranty and policies for full details.

Finishing


The storage and heating sections will be completely factory packaged and plumbed, requiring only job site hookup to

utilities, venting, and potable water inlet and outlet. The heater will be insulated to meet current ASHRAE standards,
jacketed with powder-coated steel panels, and mounted on heavy-duty channel skids. The heater will fit properly in the
space provided and installation will conform to all local, state, and national codes.

Start Up


Start up on the unit will be performed by factory trained and authorized personnel. A copy of the start up report will

be provided to the owner.

Quality Certification • Safety and Performance Standards

The heater will be have an independent test laboratory listing to safety standard UL 732. The water heaters will be

manufactured by a company that has achieved certification to the ISO 9001 International Quality System.