COMSPHERE 3900 Series Modems

7-12

September 1998

3910-A2-GN32-40

Implementing a Clone Remote Operation

WARNING

The modem begins a transfer of its own program to the remote
modem. This process takes the communication link
out-of-service for several minutes depending on the data rate
of the link. If the Clone Remote process is started and then
interrupted, the remote modem is left in a partially
programmed state in which its functional capabilities are
limited to those required to initiate and complete another
download attempt.

F1

Warning:Download
Abort_Download

F2

F3

At this point, if you do not want to continue this process, abort the transfer by selecting any
function key. This returns the modem to the DwnLoadSoftware menu. However, to continue with
the transfer, press the

key to display the Reprogram_Remote selection.

F1

Warning:Download
Reprogram_Remote

F2

F3

Press any function key to begin the transfer.

F1

RemClone Status
Establish Remote

F2

F3

The local modem’s LCD displays Establish Remote, indicating the modem is attempting to
establish a Remote Cloning Download session with the remote modem.

If unsuccessful, the modem remains in the Download Transfer mode. The LCD’s top line
displays RemClone Failed and the bottom line displays one of the following messages:

Incompat Modulat

The modems are connected, but are using a modulation scheme other
than V.33, V.32terbo, V.32bis, V.32, V.29, or TMp.

No Response

The remote modem is not a 3900 Series modem or the connection
between the two modems is poor.