IMS-4861 Passive Infrared Detection Sensor

Installation Instructions

Introduction

The IMS-4861 Passive Infrared Detection Sensor is a

dual-element passive infrared intrusion detector for use

in electronic security systems. It reduces false alarms

by eliminating background noises and nuisance stimuli.

The IMS-4861employs variable pulse-count adjustment,

thus making it adaptable for use both inside and outside

of server/equipment rooms. It is designed to connect to

the IMS-4000 Host or Node. Refer to the manufacturerʼs

instruction guide for more information.

Package Contents

(1) IMS-4861 Passive Infrared Detection Sensor
(2) Plastic drywall anchors
(2) #6 Metal tapping screws

Cabling

The Passive Infrared Detection Sensor comes with an attached 7' cable with an RJ-45 plug on the

end. If the sensor is close to the IMS-4000 Host or Node, you can plug the sensor directly to an

IMS environmental input. If the cable is too short you can use the included RJ-45 adaptor and a

longer patch cable to extend the length. For applications where the sensor may be far from the IMS

unit, you may utilize your existing network wiring infrastructure. For example, the sensor may be

installed in another room or another floor. Connect the sensor to your structured wiring network

via an RJ-45 jack. At the other end, connect a patch cable from your structured wiring patch panel

directly to the Host or Node environment input.

!

Caution:

The IMS sensors are not TCP/IP devices and therefore should not be

connected directly to any wiring infrastructure that is connected to network equipment

such as a hub, router, or switch. Sensors use RJ-45 plugs and cables similar to those

used with Ethernet devices.

Mounting

You should install the IMS-4861 sensor in a location that is most likely to intercept an intruder. The

IMS-4861 monitors motion across a 90.5º field of vision and can detect motion across the beam as

well as motion coming toward the sensor.

Note

: Avoid installing the sensor where it faces direct sunlight; faces areas that may change

temperature rapidly, or areas where there are air ducts or substantial air flows. All of these can

create false reports.

The IMS-4861 can be installed by its bracket to either a wall or a ceiling. The bracket cover is used

for mounting to walls. Remove the cover for ceiling mounting. (See Figure 1)