APPENDIX A
SPECIFICATIONS
A.1 LAN CONNECTION
• Two shielded RJ-45, 10/100Base-T, IEEE 802.3 Ethernet
• CopperLINK Connection:
Shielded RJ-45
A.2 TRANSMISSION LINE
Two-wire unconditioned twisted pair.
A.3 COPPERLINK LINE RATE AND COPPERLINK DISTANCE
• Line Rate: Up to 155 Mbps aggregate (upstream/downstream) via
Auto Rate; and 25/25 Mbps via DIP switch settings.
• Distance: Up to 5,500 ft (1.6 km)
Note
Distances depend on line rate and line conditions.
A.4 LED STATUS INDICATORS
• Power (Green)
• CopperLINK: Link (Green)
• Ethernet: Link (Green) & Activity (Flashing Green)
• Remote (Green)
• Local (Green)
A.5 POWER SUPPLY
External AC and DC options:
• AC: 120 VAC, 220 VAC, and UI (120–240 VAC)
• DC: 12 VDC, 24 VDC and 48 VDC
• Power consumption: 860mA at 5V
A.6 TEMPERATURE RANGE
-40 to 85°C
A.7 HUMIDITY
Standard
:Up to 90% non-condensing
A.8 DIMENSIONS
1.5H x 4.13W x 3.75D in.(3.81H x 10.5W x 9.53D cm)