beautypg.com

Appendix a specifications, A.1 lan connection, A.2 transmission line – Patton electronic 2173R User Manual

Page 16: A.3 copperlink line rate and copperlink distance, A.4 led status indicators, A.5 power supply, A.6 temperature range, A.7 humidity, A.8 dimensions, Specifications

background image

16

APPENDIX A

SPECIFICATIONS

A.1 LAN CONNECTION

• Two shielded RJ-45, 10/100Base-T, IEEE 802.3 Ethernet

• CopperLINK Connection:

Shielded RJ-45

A.2 TRANSMISSION LINE

Two-wire unconditioned twisted pair.

A.3 COPPERLINK LINE RATE AND COPPERLINK DISTANCE

• Line Rate: Up to 155 Mbps aggregate (upstream/downstream) via

Auto Rate; and 25/25 Mbps via DIP switch settings.

• Distance: Up to 5,500 ft (1.6 km)

Note

Distances depend on line rate and line conditions.

A.4 LED STATUS INDICATORS

• Power (Green)

• CopperLINK: Link (Green)

• Ethernet: Link (Green) & Activity (Flashing Green)

• Remote (Green)

• Local (Green)

A.5 POWER SUPPLY

External AC and DC options:

• AC: 120 VAC, 220 VAC, and UI (120–240 VAC)

• DC: 12 VDC, 24 VDC and 48 VDC

• Power consumption: 860mA at 5V

A.6 TEMPERATURE RANGE

-40 to 85°C

A.7 HUMIDITY
Standard

:Up to 90% non-condensing

A.8 DIMENSIONS

1.5H x 4.13W x 3.75D in.(3.81H x 10.5W x 9.53D cm)