beautypg.com

1 connecting the twisted-pair line interface, Connecting the twisted-pair line interface, To section 3.1 – Patton electronic 2173R User Manual

Page 10: Caution, Power jack ethernet port 1 ethernet port 2

background image

10

Figure 2.

Model 2173R panel

3.1 CONNECTING THE TWISTED-PAIR LINE INTERFACE

The Model 2173R supports communication between two peer Ethernet
LAN sites over a distance of up to 5,500 ft (1.6 km) over 24 AWG
(0.5 mm) twisted-pair wire.

Note

Actual distance and link performance may vary depending on

the environment and type/gauge of wire used.

Follow the steps below to connect the Model 2173R CopperLINK Inter-
faces.

Note

The Model 2173R units work in pairs. One of the units must be

configured as a (L) Local unit, and the other unit must be config-
ured as a (R) Remote unit. It does not matter which end is the L
and which is the R. The link is always initiated by the R unit. As
long as the L unit is powered on, the R unit can establish a link
by being powered on or by having its power reset.

1. To function properly, the two Model 2173Rs must be connected

together using twisted-pair, unconditioned, dry, metal wire, between
19 (0.9mm) and 26 AWG (0.4mm). Leased circuits that run through
signal equalization equipment are not acceptable.

The Interconnecting cables shall be acceptable for
external use and shall be rated for the proper applica-
tion with respect to voltage, current, anticipated tem-
perature, flammability, and mechanical serviceability.

CopperLINK

twisted-pair

RJ-45 interface

2173R

(RJ-45)

Power

jack

Ethernet

port 1

Ethernet

port 2

Eth

ern

et 1

Link

Pow

er

CopperLink 2173R

Ruggedized Ethernet Extender

Ethe

rnet

2 1

Pow

er

5V; 0

.6A

Line

Eth

ern

et 2

Rem

ote

Loc

al

CAUTION