Registration of input signal data

• The data of 96 input signals can be registered.
• The signals supporting the installed input module are input and their data registered.
• The memories are numbered over 12 pages (A to L: 8 data items can be registered on each page),

and the data is registered in the unused memory with the lowest number. If all the memories are used,
the data of the old signals is overwritten in sequence.

• The names of the registered data are automatically determined by the input signals and memory

numbers.

The input signal data must be registered because it is not registered on shipment of the projector.

Note

Renaming the registered signals

Registration of new data

When a new signal is supplied, press the “MENU” button on the remote control or operating section of the main
unit. When its data has been registered, the MAIN MENU screen is displayed.

Press the “MENU” button.

The MAIN MENU screen will be displayed.

Select “SIGNAL LIST” with the

and

buttons.

Note

MAIN MENU
PICTURE
POSITION
ADVANCED MENU
LANGUAGE
OPTION
TEST PATTERN
SIGNAL LIST
SECURITY

:MENU SELECT
ENTER:SUB MENU

REGISTERED SIGNAL LIST

A1:SVGA72-A1

RGB1

– – –

A2:SVGA72-A2

RGB1

– – –

A3:SVGA72-A3

RGB1

– – –

A4:SVGA72-A4

RGB1

– – –

A5:SVGA72-A5

RGB1

– – –

A6:SVGA72-A6

RGB1

– – –

A7:SVGA72-A7

RGB1

– – –

A8:SVGA72-A8

RGB1

– – –

:SELECT ENTER:DETAILS STD:DELETE

REGISTERED SIGNAL STATUS

NAME:

SVGA72-A2

MEMORY NO:

A2

S.S.NO:

– – –

INPUT NO:

RGB1

fH:

48.08kHz

fV:

72.17Hz

SYNC. STATE:

H(POS)
V(POS)

ENTER:CHANGE NANE

Press the “ENTER” button.

The REGISTERED SIGNAL LIST screen will be
displayed. The memories extend over 12 pages (A
to L with 8 data items each, giving a total of 96
memories).

Select the signal whose details are to
be displayed with the

, , and

buttons.

Press the “ENTER” button.

The REGISTERED SIGNAL STATUS screen will
be displayed.

• The data items including the input signal

name, memory number, signal selector
input number, input terminal, frequency
and sync signal are automatically
identified and displayed.

• When the “MENU” button is pressed, the

REGISTERED SIGNAL LIST screen is
restored.