Setup procedures, Displaying the setup menu, Setup menu – Panasonic WV-CM1780 User Manual
Page 9: Unit address (unit address)
9
SETUP PROCEDURES
This monitor offers various onscreen menus for setting user
preferences.
In the COMMUNICATION SETUP Menu, you can set the
parameters for communication between the System
Controllers and the Monitors.
■
Displaying the Setup Menu
To display the Setup Menu, follow the procedure shown
below.
1. Confirm that the cameras and peripherals are connect-
ed correctly and securely.
2. Turn the power of the monitor on by pressing the
POWER
button.
3. Press the
MENU
button for 5 seconds or more.
At first the Display Setting menu described on page 11
appears, and then the COMMUNICATION SETUP
menu shown below.
The following buttons are available in this Setup menu.
C
:
Moves the cursor down.
D
:
Moves the cursor up.
-
:
Selects the mode or parameter.
+
:
Selects the mode or parameter.
4. To finalize the settings and return to normal viewing,
press the
MENU
button.
COMMUNICATION SETUP
UNIT ADDRESS 1
CAM CONFIG
BAUD RATE 9600
DATA BIT 8
PARITY CHECK NONE
STOP BIT 1
WAIT TIME OFF
SETUP DISABLE
■
Setup Menu
As shown below, the Setup Menu has seven main sub-
menus.
One of these, CAM CONFIG, is further divided into addi-
tional submenus.
1. After selecting the Setup Menu on the monitor screen,
move the cursor to SETUP DISABLE with the C or D
button, then press the - or + button.
Display of SETUP ENABLE in the Setup menu indicates
that setup is enabled.
2. Move the cursor to the desired item with the C or D
button.
3. Select the desired item parameter with the - or +
button.
4. Press the
MENU
button to store the settings and return
to normal viewing.
●
Unit Address (UNIT ADDRESS)
This item lets you set the unit address of the monitor in the
system for RS-485 communication.
1. Move the cursor to the UNIT ADDRESS parameter with
the C or D button.
2. Select the unit address number to be used for RS-485
communication with the - or + button.
Select a parameter value between 1 and 99.
The factory default setting is 1.
COMMUNICATION SETUP
UNIT ADDRESS 1
CAM CONFIG
BAUD RATE 9600
DATA BIT 8
PARITY CHECK NONE
STOP BIT 1
WAIT TIME OFF
SETUP ENABLE
COMMUNICATION SETUP
UNIT ADDRESS 1
CAM CONFIG
BAUD RATE 9600
DATA BIT 8
PARITY CHECK NONE
STOP BIT 1
WAIT TIME OFF
SETUP ENABLE