Camera configuration (cam config), Baud rate (baud rate), Data bit (data bit) – Panasonic WV-CM1780 User Manual
Page 10: Parity check (parity check), Stop bit (stop bit), Wait time (wait time), Camera configuration (cam con- fig)
10
●
Baud Rate (BAUD RATE)
This item lets you set the transmission speed for RS-485
communication.
1. Move the cursor to the BAUD RATE parameter with the
C or D button.
2. Select the desired transmission speed shown below
with the - or + button.
The factory default setting is 9 600 bps.
●
Data Bit (DATA BIT)
This item lets you set the number of data bits for RS-485
communication.
The factory default setting is 8 bit and fixed.
●
Parity Check (PARITY CHECK)
This item lets you set the parity bit for RS-485 communica-
tion.
1. Move the cursor to the PARITY CHECK parameter with
the C or D button.
2. Select NONE, EVEN or ODD for parity check with the
- or + button.
The factory default setting is NONE
●
Stop Bit (STOP BIT)
This item lets you set the number of stop bits for RS-485
communication.
1. Move the cursor to the STOP BIT parameter with the C
or D button.
2. Select either 1 or 2 for number of stop bits with the -
or + button.
The factory default setting is 1 bit.
●
Wait Time (WAIT TIME)
This item lets you set the waiting time in milli-seconds (ms)
to retry after confirming that no data is received from the
system controller for RS-485 communication.
1. Move the cursor to the WAIT TIME parameter with the
C or D button.
2. Select OFF, 100, 200, 400, 1 000 ms for the wait time
with the - or + button.
When no transmission is needed, select OFF.
The factory default setting is OFF (no retry).
●
Camera Configuration (CAM CON-
FIG)
This item lets you set numbers for the input from sys-
tem cameras for RS-485 communication.
1. Move the cursor to CAM CONFIG with the C or D but-
ton, then press the - or + button. The CAMERA
CONFIG menu shown below will appear on the monitor
screen.
2. Move the cursor to the input parameter to be edited
with the C or D button, then select a number with the
- or + button.
Select a parameter value between 001 and 128.
The factory default setting for each input is shown
below.
A CH
001
B CH
002
S-VIDEO
003
Note:
Make sure not to assign the same number to
more than one system camera for RS-485 commu-
nication.
3. Repeat the above procedure to edit other input.
4. After completing the settings, press the
MENU
button
to return to the previous setup menu.
COMMUNICATION SETUP
UNIT ADDRESS 1
CAM CONFIG
BAUD RATE 9600
DATA BIT 8
PARITY CHECK NONE
STOP BIT 1
WAIT TIME OFF
SETUP ENABLE
CAMERA CONFIG
INPUT CH CAM NO.
A CH 001
B CH 002
S-VIDEO 003
2 400 4 800 9 600 19 200