beautypg.com

Camera configuration (cam config), Baud rate (baud rate), Data bit (data bit) – Panasonic WV-CM1780 User Manual

Page 10: Parity check (parity check), Stop bit (stop bit), Wait time (wait time), Camera configuration (cam con- fig)

background image

10

Baud Rate (BAUD RATE)

This item lets you set the transmission speed for RS-485
communication.

1. Move the cursor to the BAUD RATE parameter with the

C or D button.

2. Select the desired transmission speed shown below

with the - or + button.

The factory default setting is 9 600 bps.

Data Bit (DATA BIT)

This item lets you set the number of data bits for RS-485
communication.

The factory default setting is 8 bit and fixed.

Parity Check (PARITY CHECK)

This item lets you set the parity bit for RS-485 communica-
tion.

1. Move the cursor to the PARITY CHECK parameter with

the C or D button.

2. Select NONE, EVEN or ODD for parity check with the

- or + button.

The factory default setting is NONE

Stop Bit (STOP BIT)

This item lets you set the number of stop bits for RS-485
communication.

1. Move the cursor to the STOP BIT parameter with the C

or D button.

2. Select either 1 or 2 for number of stop bits with the -

or + button.

The factory default setting is 1 bit.

Wait Time (WAIT TIME)

This item lets you set the waiting time in milli-seconds (ms)
to retry after confirming that no data is received from the
system controller for RS-485 communication.

1. Move the cursor to the WAIT TIME parameter with the

C or D button.

2. Select OFF, 100, 200, 400, 1 000 ms for the wait time

with the - or + button.
When no transmission is needed, select OFF.

The factory default setting is OFF (no retry).

Camera Configuration (CAM CON-

FIG)

This item lets you set numbers for the input from sys-
tem cameras for RS-485 communication.

1. Move the cursor to CAM CONFIG with the C or D but-

ton, then press the - or + button. The CAMERA
CONFIG menu shown below will appear on the monitor
screen.

2. Move the cursor to the input parameter to be edited

with the C or D button, then select a number with the
- or + button.
Select a parameter value between 001 and 128.

The factory default setting for each input is shown
below.

A CH

001

B CH

002

S-VIDEO

003

Note:

Make sure not to assign the same number to

more than one system camera for RS-485 commu-
nication.

3. Repeat the above procedure to edit other input.

4. After completing the settings, press the

MENU

button

to return to the previous setup menu.

COMMUNICATION SETUP
UNIT ADDRESS 1
CAM CONFIG
BAUD RATE 9600
DATA BIT 8
PARITY CHECK NONE
STOP BIT 1
WAIT TIME OFF

SETUP ENABLE

CAMERA CONFIG

INPUT CH CAM NO.
A CH 001
B CH 002
S-VIDEO 003

2 400 4 800 9 600 19 200