Figure 13-1 Wiring Diagram

13

Diagrams

DISPLAY

X1-8

X5-5

X5-13

X5-6

X5-12

INTEGRATED CONTROL

BLOWER

X1-1

X2-2

X2-1

X1-7

GAS
VALVE

FLAME
ROD

SPARK

ROD

W/R

G

R

R

T

W

BK

G

R

1

3

2

W

G

BOX DEPICTS

OPTIONAL ITEMS

WIRING DIAGRAM
LBL2364 REV D

INLET
SENSOR

OUTLET
SENSOR

FLUE
SENSOR

MANUAL RESET
HI-LIMIT

BLOCKED
DRAIN

X5-8

X5-1

X5-2

X5-9

X5-7

X5-14

X5-11

X5-3

X5-4

X5-10

BK

R

W

Y

BL

PR

OR

P

GY

BL

PR

OR

P

BL

1 2

4 5

3

SYSTEM

SENSOR

(AUX) DWH

TANK

SENSOR

OUTDOOR

SENSOR

0-10V

+

-

RS485

A

B

CONNECTION BOARD

CN3

X4

X1-3

X1-2

X1-6

X1-4

OR

PR

BK

BR

BK

W

ON/OFF

SWITCH

SHIELD

SHIELD

BK

Y

FLOW

SWITCH

GAS

PRESSURE

SWITCH

AUX.

DEVICE

PROVING

LOW

WATER

CUT-OFF

CN5-1

CN4-6

CN4-1

CN4-9

CN4-3

CN4-2

X6-9

X6-3

X6-4

X6-5

X6-10

BR

Y

P

BK

OR

CN4-11

CN4-12

CN4-10

CN4-4

ALARM

CONTACTS

RUN-TIME

CONTACTS

X3-1

X3-3

X3-4

X3-2

R

R

PR

PR

AUX.

DEVICE

PILOT

SUPPLY

CN4-8

X6-8

Y

DHW

THERMOSTAT

CN4-5

X6-1

W

ROOM

THERMOSTAT

ZONE

CONTROL

CN4-7

CN4-13

X6-2

X6-6

BL

GY

R

EXTERNAL

CONTROL

CAUTION

HIGH VOLTAGE SPARK LEAD

CN5-3

CN5-4

CN5-2

24 VAC

COM

TR1

X8

120 VAC

LOW VOLTAGE

HIGH VOLTAGE

X3

PC

INTERFACE

CN4-14

CN1-12

CN1-11

CN1-10

CN1-9

CN1-8

CN1-7

CN1-6

CN1-5

CN1-4

CN1-3

CN1-2

CN1-1

Notes:
1. All wiring must be installed in accordance with: local, state, provincial and national code requirements per either N.E.C. in USA or C.S.A. in Canada.
2. If any original equipment wire as supplied with the appliance must be replaced, it must be replaced with wire having same wire gauge (AWG) and rated for a
minimum of 105°C. Exceptions: Replacement high voltage spark lead and ribbon cables must be purchased from the factory. Use of a non-approved spark lead
or ribbon cables can lead to operational problems which could result in non-repairable damage to the integrated controller or other components.
3. Actual connector block locations may vary from those shown on diagrams. Refer to actual components for proper connector block locations when using
diagrams to troubleshoot unit.

CN2-1

CN2-2

CN2-3

CN2-4

CN2-5

CN2-6

CN2-7

CN2-8

CN2-9

CN2-10

CN2-11

CN2-12

CN2-13

CN2-14

CN2-15

CN2-16

CN1

CN2

CN5

CN4

CN3

BELL JUMPER

ALARM B

E

L

L

S

IL

E

NCING S

W

ITCH

S6

S4

S5

S2

S1

S3

OR

JUNCTION

BOX

120V
SUPPLY

GND

N

GND

L

SYSTEM
PUMP

BOILER
PUMP

DHW
PUMP

RELAY

BOARD

OR

OR

BR

BR

PR

PR

X1-5

W

CN2-4

CN2-2

CN2-3

CN2-1

K1

K2

K3

CN1-5

CN1-6

CN1-3

CN1-4

CN1-1

CN1-2

AIR PRESS. SWITCH

SOLENOID

VALVE
RELAY

RESIS

T

OR