Installation, Technical specifications - power wave 450 – Lincoln Electric INVERTEC POWER WAVE 450 10391 User Manual
Page 8
TECHNICAL SPECIFICATIONS - POWER WAVE 450
Input Voltages:
230
460
Input Currents
@ 500A/40 VDC
76
38
@ 450A/38 VDC
65
32
Duty Cycle
Amps
Volts at Rated Amperes
230/400/460 - 60% Duty Cycle
450
38 VDC
230/400/460 - 100% Duty Cycle
400
38 VDC
Constant Open
Continuous
Process
Circuit Voltage
Current Range
Current Ranges
75 Volts
5-520 Amps
GMAW 50-520 Amps
FCAW 40-520 Amps
STICK 30-520 Amps
Pulse
Pulse
Pulse and Background
Pulse
Current Range
Voltage Range
Time Range
Frequency
5-750 Amps
5-55 Volts
100 Microsec - 3.3 Sec
0.15 - 1000 Hz
Type 75°C
Type 75°C
Type 75°C
Input
Duty
Input Ampere
Copper Wire in
Ground Wire in
(Super Lag)
Voltage/
Cycle
Rating on
Conduit
Conduit
or Breaker
Freqency
Nameplate
AWG[IEC]
AWG[IEC]
Size (Amps)
Sizes (MM
2
)
Sizes (MM
2
)
230/50-60
60%
76
4 (25)
8 (10)
80
460/50-60
60%
38
8 (10)
10 (6)
45
230/50-60
100%
65
4 (25)
8 (10)
80
460/50-60
100%
32
8 (10)
10 (6)
45
Height
Width
Depth
Weight
905 mm
515 mm
1010 mm
137.9 kg
35.6 in.
20.3 in.
39.8 in.
303.5 lbs.
0° to 40°C
-50° to 85°C
INSTALLATION
A-1
A-1
POWER WAVE 450
INPUT - THREE PHASE ONLY
RATED OUTPUT
RATED OUTPUT
RECOMMENDED INPUT WIRE AND FUSE SIZES
PHYSICAL DIMENSIONS
OPERATING TEMPERATURE RANGE STORAGE TEMPERATURE RANGE