1.

LCD DISPLAY WINDOW: Power up the machine
with this overlay in place. When the Power Wave
is turned on, the following message appears in the
display window for a few seconds:

LINCOLN ELECTRIC

Version X.X

This display is followed by:

OVERLAY ID

NUMBER = 0

This message is then replaced by the following
message:

POWER WAVE

SETUP

2.

WATER COOLER ON/OFF KEY: Press this key to
toggle the water cooler between being enabled
and disabled. The present status of the water
cooler is indicated by the “WATER COOLER ON”
light.

3.

WATER COOLER PRESSURE LIGHT: This light
indicates whether enough water pressure exists
for normal water cooler operation. If the water
cooler loses the required pressure it will shut down
within a couple of seconds and the water cooler
pressure light will turn off.

If the water cooler does not have enough pressure
to operate when enabled, the machine also
sounds a buzzer.

4.

PRIME WATER COOLER KEY: The water cooler
may have to be primed if there is not enough pres-
sure in the water cooler hose for operation. Make
sure that the water cooler has been turned on
before it is primed. (The “WATER COOLER ON”
light should be turned on.) To prime the water
cooler, hold the PRIME WATER COOLER key
down. While this key is pressed, the display will
show:

PRIME WATER

COOLER

OPERATION

B-16

B-16

POWER WAVE 450

1 LCD DISPLAY WINDOW
2 WATER COOLER ON/OFF KEY
3 WATER COOLER PRESSURE LIGHT
4 PRIME WATER COOLER KEY

5 WIRE FEEDER 1+/- POLARITY KEY
6 WIRE FEEDER 1 ELECTRODE SENSE LEAD KEY
7 WIRE FEEDER 1 WORK SENSE LEAD KEY

SETUP OVERLAY

The Setup Overlay is used to control the water cooler operation (on/off and prime the water cooler), and to set
up the voltage sensing configuration of the machine and wire feeder(s) connected to the Power Wave. See Figure
B.9.

FIGURE B.9 – SETUP OVERLAY

WARNING

THE LINCOLN ELECTRIC COMPANY CLEVELAND, OHIO USA

C COPYRIGHT 1994

R

L9660 SETUP OVERLAY

WATER

COOLER

ENABLE

WATER

COOLER

PRIME

WATER COOLER PRESSURE

POLARITY

ELECTRODE

WORK

+POLARITY

ELECTRODE

WATER COOLER CAN ONLY BE

PRIME THE WATER COOLER
UNTIL WATER COOLER PRESSURE

SENSE LEAD

WORK SENSE

LEAD ENABLED

LEAD

SENSE

LEAD

SENSE

WATER COOLER SETUP

WIRE

WIRE

FEEDER 2

FEEDER 1

+POLARITY

ELECTRODE

SENSE LEAD

WORK SENSE

LEAD ENABLED

+/ -

WORK
SENSE

LEAD

ELECTRODE

SENSE

LEAD

POLARITY

+/ -

WATER COOLER ENABLED

PRIMED WHEN IT IS ENABLED.

1

3

2

4

5

6

7

LIGHT TURNS ON.

ENABLED

ENABLED