PostScript
4-30
manualfeedtimeout
/manualfeedtimeout
integer
def
is an integer key in
statusdict
that works with the
ManualFeedTimeout
page
device parameter to determine the manualfeed timeout for a given page.
If during a print job,
manualfeedtimeout
is defined as an integer value in
statusdict
, that value is used instead of the
ManualFeedTimeout
page device
parameter.
The value of the
ManualFeedTimeout
page device parameter and
manualfeedtimeout
key in
statusdict
are independent of each other; the value
of one does not affect the value of the other.
0
disabled
1...65355
seconds
An
undefined
error results if
manualfeedtimeout
is queried before the value is
set.
Errors:
stackoverflow, undefined
newsheet
— newsheet —
causes the current page to start on the front side of a new sheet.
Error:
none
pagecount
— pagecount
integer
queries the value of the
PageCount
system parameter. An integer is returned on
the stack indicating the current page count.
This operator is equivalent to executing the following PostScript emulation
sequence:
currentsystemparams /PageCount get
Error: