System Options

For most installations the factory settings for the system will be
appropriate. To customize the system, enter programming mode via
telephone or keypad.
Use the programming worksheet supplied to log any system option
changes prior to entering it into the system.
For each of the following steps, enter the Master Password and enter
Programming Mode (if the unit is not already in that mode). Exit
Programming Mode when all programming is complete.

System Display Language

The factory default language is English. Three other languages can be
selected as the language for the user and programming displays.

NOTE: This step cannot be performed remotely through the

telephone.

NOTE: The system supports one display language at a time.

1. Press

2. Choose a language:

Enter 1 for English
Enter 2 for Spanish
Enter 3 for French
Enter 4 for Portuguese

3. Press

Keypad Lockout Count

The system counts the number of invalid Entry Codes entered at the
keypad. If the invalid entries exceeds the lockout count number, the
keypad is locked out for 90 seconds. The factory setting for the lockout
count is three. The lockout value can be from one to nine.

1. Press

2. Enter the number for the lockout count (1-9).

3. Press

Access Relay Activation Time

The factory setting will cause the access relay to activate for 4 seconds.
The activation time can be set from 4-99 seconds to accommodate
different types of access control devices.

1. Press

2. Enter the time (in seconds) for access relay to stay activated (04-99)

3. Press




PPN 38

38#LANG#

LANG = SYSTEM DISPLAY LANGUAGE
1 = ENGLISH 2 = SPANISH
3 = FRENCH 4 = PORTUGUESE

SYSTEM DISPLAY LANGUAGE

FACTORY SETTING: ENGLISH

PPN 51

51#COUNT#

COUNT = NUMBER (1-9) OF INCORRECT ENTRIES

THAT WILL CAUSE A 90 SECOND LOCKOUT

KEYPAD LOCKOUT COUNT

FACTORY SETTING: 3 TRIES

PPN 52

52#SECONDS#

SECONDS = ACTIVATION TIME (04-99 SECONDS)

ACCESS RELAY ACTIVATION TIME

FACTORY SETTING: 4 SECONDS

STANDARD PROGRAMMING METHOD