Linear ACCESS AE-100 User Manual
Page 19
19
FUNCTION CODE
LOCAL PROGRAMMING
TELEPHONE PROGRAMMING
70
MAXIMUM VISITOR
TALK TIME
If for some reason the resident
does not press the telephone
keys to grant or deny access or
does not hang up, the system
will automatically disconnect the
visitor after 60 seconds.
At ten and fi ve seconds before
the disconnect a tone will sound
on the telephone to remind
the resident of the pending
disconnect. The resident can
extend the talk time by pressing
the # key on their telephone. The
disconnect time can be adjusted
from 10-180 seconds.
Step 1 Enter Function Code 70, then press #.
Step 2 The display will show the current talk time setting.
Enter the new talk time (010-180 seconds).
Step 3 Press #.
Step 1 Enter Function Code 70 and
press #, one short beep sounds.
Step 2 Enter the new talk time (010-180 seconds)
and press #, two short beeps sound.
Step 3 Press #, two short beeps sound
71
ACCESS RELAY
ACTIVATION TIME
The factory setting will cause
the access relay to activate for
4 seconds. The activation time
can be set from 4-99 seconds to
accommodate different types of
access control devices.
Step 1 Enter Function Code 71, then press #.
Step 2 The display will show the current access relay
activation time setting. Enter the new access
relay activation time (04-99 seconds).
Step 3 Press #.
Step 1 Enter Function Code 71 and
press #, one short beep sounds.
Step 2 Enter the new access relay
activation time (04-99 seconds).
Step 3 Press #, two short beeps sound.
72
KEYPAD LOCKOUT
COUNT
The system counts the number
of invalid Access Codes entered
at the keypad. If the invalid
entries exceeds the lockout count
number, the keypad is locked
out for 90 seconds. The factory
setting for the lockout count is
three. The lockout value can be
from one to nine.
Step 1 Enter Function Code 72, then press #.
Step 2 The display will show the current lockout count.
Enter the new lockout count (1-9 tries).
Step 3 Press #.
Step 1 Enter Function Code 72 and
press #, one short beep sounds.
Step 2 Enter the new lockout count (1-9 tries).
Step 3 Press #, two short beeps sound
T A L K T I M E : 0 6 0
O P E N T I M E : 4
L O C K - O U T C O U N T : 3
ALTERNATE PROGRAMMING METHOD