beautypg.com

Voltage waveforms, F-23, 0 v 5 ms 0 volts – Lincoln Electric POWER MIG SVM157-A User Manual

Page 57: Troubleshooting and repair

background image

TROUBLESHOOTING AND REPAIR

F-23

F-23

POWER MIG 200

TYPICAL OUTPUT VOLTAGE WAVEFORM - MACHINE LOADED

(MAX TAP “G”)

10.0 V

5 ms

0 Volts

This is a typical DC output voltage wave-
form generated from a properly operat-
ing machine. Note that each vertical
division represents 10 volts and that
each horizontal division represents 5
milliseconds in time. The machine was
loaded with a resistance grid bank.

NOTE: Scope probes connected at

machine output terminals: (+)
probe to electrode, (-) probe to
work.

Volts/Div.................................10V/Div

Horizontal Sweep.................5 ms/Div

Coupling........................................DC

Trigger....................................Internal

SCOPE SETTINGS

MACHINE LOADED TO 200 AMPS AT 22 VDC