Land Pride RC5020 User Manual
Page 46

44
Section 5: Maintenance & Lubrication
RC5020 (540 RPM) and RCM5020 (1000 RPM) Rotary Cutters 318-474M
5/29/13
CV Main Driveline Joints & Shields
CV = Constant Velocity
Type of Lubrication: Multi-purpose Grease
For instructions on how to access grease zerks shown in
Figure 5-12, see “Accessing CV Driveline Joints” on
page 45.
•
The constant velocity joint should be greased in a
straight position forcing grease through the passages
and into the cavity. After lubrication, grease should be
visible around the ball joints.
•
Grease fittings are located on the u-joints and should
be lubricated every 8 hours of operation.
IMPORTANT: To extend the life of the constant
velocity joint, extensive lubrication must be
performed every 8 hours of operation.
8
Hrs
Drivelines with external grease point for Profile Tube
Drivelines with internal grease point for Profile Tube
23556
8-10 pumps
Zerk Located through slot in tube
23565
Zerk Located on end of tube
CV Main Driveline Profile Tubes
CV = Constant Velocity
Type of Lubrication: Multi-purpose Grease
Quantity = Coat Generously
IMPORTANT: To extend the life of the constant
velocity joint, the grease zerk for the profile tubes
must be lubricated every 8 hours.
8
Hrs
Drivelines with external grease point for Profile Tube
Figure 5-12
Drivelines with internal grease point for Profile Tube
23556
2 pumps each
2-3 pumps
4-6 pumps
4-5 pumps
2-3 pumps
23565
Access Zerk through hole in shield