E-5

TROUBLESHOOTING

E-5

PRECISION TIG 375

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local

Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

PRESET & OUTPUT CONTROL PROBLEMS

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENTS

RECOMMENDED

COURSE OF ACTION

Meter does not display preset

High output current in both DC & AC

polarities regardless of preset

High output current in DC polarity

regardless of preset, o.k. in AC polar-

ity

In 2-step Tig, output stays on for

more than downslope time after trig-

ger open (machine with Advanced

Control panel only)

Output stays on after releasing

hand/foot Amptrol (machine with

Advanced Control panel only)

1. Faulty potentiometer R1 or its con-

nection

2. Bad connection at P9 of Control

PC board

3. Faulty Advanced Control PC board

( if present ) or its connection to

the main Control PC board

4. Missing plug P3 on Control board

or bad connection at P3 when an

Advanced Control PC board is not

present

1. Bad connection at P6 of Control

PC board

2. Bad shunt connection

3. Faulty Control PC board

4. Faulty SCR bridge

1. Shorted free wheeling diode D1

1. Bad 2/4 step switch or its connec-

tion

2. Bad connection at P1 of Advanced

Control PC board

1. Downslope is not set at min.

2. Bad Downslope potentiometer

R12 or its connection

If all recommended possible areas

of

misadjustment

have

been

checked and the problem persists,

Contact

your

local

Lincoln

Authorized Field Service Facility.