Electrical Control Board Replacement

Pressure Calibration on the Electrical Control Board

1. Remove electrical cover.
2. Disconnect sensor lead from Electrical Board.
3. Disconnect two clutch leads on Electrical Board

from leads on clutch.
4. Using a 1/16" allen, loosen set screw in Pressure

Con trol Knob and remove knob.

5. Using a 1/2" nutdriver or 1/2" deep socket, remove

nut from pressure control shaft. This will allow

removal of elec tri cal con trol board from frame.
6. Replace Electrical Board Assembly in reverse order.

Adjust pressure as per procedure below, "Pressure

Cal i bra tion on the Electrical Control Board".

1. Turn "Pressure Calibration" Trimpot adjustment on

elec tri cal control board in the counter clockwise

direction at least 15 revolutions.
2. Connect 5000 psi glycerine pressure guage on output

of pump between fl uid pump & airless hose to

monitor Fluid Pump Pres sure.
3. Turn Prime/Pressure Relief Valve to the open

(Prime) position. Start engine and run at maximum

RPM. Turn Pres sure Con trol Knob to maximum

position (fully clock wise).
4. Using an insulated screwdriver, adjust "Pressure

Cal i bra tion" Trimpot by turn ing clock wise until the

clutch en gag es. When the clutch en gag es the pump

will com mence Prim ing. When pump is primed, turn

the Prime/Pressure Relief Valve to the Closed (Pres

sure) Position

5. Trigger gun. The pressure should drop approximately

350-400 psi (when using a 3/8" hose), the clutch will

en gage and build pres sure to 3000 psi and disengage.

Trig ger gun several times to en sure proper pressure

set ting.

6. Turn Pressure Control Knob to minimum position. The

clutch should disengage and pump stop moving.

7. Secure leads with tie strap.

8. Replace cover on unit. Ensure the leads are not

pinched or damaged in the process of replacing covers.

The pump will begin to pressurize and the clutch will dis-

en gage at a low pressure. Continue turning the Trimpot

clockwise to increase pressure to 3000 psi.