beautypg.com

Spray gun operation – AIRLESSCO Spray & Stripe 3600 User Manual

Page 16

background image

Spray Gun Operation

Reversible

Spray Tip

Tip Guard

Trigger Guard

MAJOR COMPONENTS OF SPRAY GUN &

REVERSIBLE REV-TIP

SPRAY GUN

Attach spray gun to airless unit and tighten fittings securely.

Set the gun safety latch. (Also may be called gun safety

lock, or trigger lock)
* The gun safety latch should always be set when the gun is

not being triggered.
Read all warnings and safety precautions supplied with the

spray gun and in product manual.

SPRAY TIP ASSEMBLY

1. Be sure the pressure relief procedure is followed

before assembling tip and housing to the gun.
2. Insert REV-TIP™ cylinder into the REV-GUARD

(guard housing assembly).

3. Guide the metal seat into REV-GUARD™ (guard

housing assembly) through the retaining nut & turn

until it seats against the cylinder.
4. Insert the O-Ring gasket onto the metal seat so that it

fits into the grooves.
5. Finger tighten REV-GUARD™ retaining nut onto the gun.
6. Turn guard in the desired position.
7. Completely tighten the retaining nut.

TO REMOVE CLOGS FROM SPRAY TIP

1. Lock gun safety latch.
2. Turn REV-TIP™ handle 180 degrees.
3. Disengage trigger lock and trigger gun into

the pail.
4. If the REV-TIP™ handle appears locked

(resists turning), loosen the retaining nut. The

handle will now turn easily.
5. Engage gun safety latch and return handle to

the spray position.

CLEANING SPRAY GUN

CLEANING FILTER IN GUN HANDLE

Immediately after the work is finished, flush the gun out

with a solvent. Brush pins with solvent and oil them

lightly so they will not collect dried paint.

To clean the filter, use a brush dipped in an

appropriate solvent. Change or clean filters

at least once a day. Some types of latex may

require a filter change after four hours of

operation

.

Gun Handle. Unscrew

from gun head to service

filter inside.

Gun Safety

Latch or Lock

14

Press up here & pull gently

to remove trigger guard

O-Ring Gasket

Metal Seat

REV-TIP™ Cylinder

Retaining Nut

Spray Position Shown

Reverse to

Unplug

REV-GUARD™

Guard Housing Assembly

Retaining Nut

Part # 561-026

Part # 561-029

Part # 561-XXX

G Thread 7/8" 561-002

F Thread 11/16" 561-001