Servicing the Piston Rod - Outlet Valve

331-196

331-195

Piston

DISASSEMBLY OF THE OUTLET VALVE

REFER TO FIGURE 3

1. Disconnect the Fluid Pump following instructions on page 17 .

2. Place piston holder (331-195) in a vise. Slide piston into

the holder & lock in place with a 3/8” dowel (331-196).
3. Use a 1/4” allen wrench to unscrew the outlet seat retainer

(331-026) from the piston.
4. Remove the outlet seat (331-026), O-ring (331-100) and

outlet ball (331-027).
5. Inspect outlet ball & seat for wear. Replace as necessary.
6. While piston is still locked in the holder, install parts

back into the piston in the following order:

ball, outlet seat and O-ring

Before reinstalling the outlet seat support, apply two drops of

Loctite No. 242 (blue) on the threads & torque to 20 ft-lbs.

Servicing the Suction Assembly

REFER TO FIGURE 4

1. Un-thread and remove suction nut from the fl uid pump body.
2. Remove suction seat (331-409), O-ring (106-011), suction ball

(331-030) and suction retainer (331-029).
3. Clean all parts and inspect them for wear or damage, replacing

parts as needed.
4. Clean inside of the fl uid pump body.
5. Reassemble lower suction valve assembly by placing the

suction seat (331-409), O-ring (106-011), suction ball (331-030)

& suction ball guide (331-029) in the suction nut (331-034) &

FIGURE 3

FIGURE 4

18

NOTE: Airlessco LP pump tool kit 188-197 is suggested for this task.

Kit includes: Packing Tightening Bar (189-211), Packing Removal Tool (331-153),

Piston Holder (331-195), 3/8” dowel (331-196).