Lenovo RD120 User Manual
Page 60

1
RAID
controller
4
Battery
mounting
tabs
2
Battery
cable
5
Battery
mounting
clips
3
Battery
6
Battery
cable
connector
9.
Turn
the
new
ServeRAID-8k
SAS
controller
so
that
the
keys
on
the
bottom
edge
align
correctly
with
the
connector.
10.
Firmly
press
the
ServeRAID-8k
SAS
controller
straight
down
into
the
connector
by
applying
pressure
on
both
ends
of
the
controller
simultaneously.
The
retaining
clips
snap
into
the
locked
position
when
the
controller
is
firmly
seated
in
the
connector.
Note:
If
there
is
a
gap
between
the
controller
and
the
retaining
clips,
the
controller
has
not
been
correctly
installed.
In
this
case,
open
the
retaining
clips
and
remove
the
controller;
then,
reinsert
the
controller.
11.
Remove
the
battery
from
the
ServeRAID-8k
SAS
Controller
package.
12.
Slide
the
battery
mounting
tabs
into
the
battery
mounting
clips
on
the
server
wall
that
is
next
to
the
ServeRAID
SAS
controller
connector.
13.
Connect
the
battery
to
the
ServeRAID-8k
SAS
Controller.
14.
Replace
the
air
baffle
over
the
DIMMs
(see
15.
Replace
the
riser-card
assembly
(see
If
you
have
other
optional
devices
to
install
or
remove,
do
so
now.
Otherwise,
go
to
Notes:
1.
When
you
restart
the
server
for
the
first
time
after
you
install
a
ServeRAID-8k
SAS
controller,
the
monitor
screen
remains
blank
while
the
controller
initializes
46
ThinkServer
RD120
Types
6444,
6445,
6446,
and
6447:
User
Guide