beautypg.com

Caution – Lennox Hearth EDVI25 User Manual

Page 6

background image

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE

6

Small Area Paint Touch-up

The finish of the insert body and surround

(optional) is a high-quality powdercoat. Only

use factory supplied powdercoat paint for

touch-ups, cat. no. 90L74.
Do not attempt to repaint the insert until the

finish is completely cured (see Burn-In Period

on this page). If the surface later becomes

stained or marred, it may be lightly sanded and

touched up with spray paint.
Paint is available at your local authorized Lennox

Hearth Products dealer. Never attempt to paint

a hot insert.

Inspect Wiring

Inspect and clean all wire connections. Ensure

that there is no melting or damage. Inspection

should include:

• Terminals at the valve

• On/Off switch

• Wall thermostat, remote control, or control

kit (optional parts)

Refer to wiring diagrams on Pages 13

& 14.

CAUTION

Label all wires prior to discon-

nection when servicing con-

trols. Wiring errors can cause

improper and dangerous appli-

ance operation.

Air Hood

Remove Screws

Figure 7

EDVI30

9. ENSURE THAT GAS SUPPLY IS SHUT OFF.

Disconnect gas line fitting at the valve (for

models EDVI30 & EDVI35). See Figure 8.

Disconnect Gas

Line Fitting

Figure 8

10. Disconnect the two burner circuit wires

from the valve terminals (see Figure 9).

Disconnect Blue

Wires From Valve

Terminals

Figure 9

TH

TP

TP

TH

8. (EDVI30 only) Remove the two screws

shown in Figure 7, then lift out air hood.

11. (EDVI30 only) Remove the screws around

the perimeter of the gas valve train, then

lift out and set aside (see Figure 11).

12. (EDVI35 only) Remove the screws around

the perimeter of the blower access panel,

then lift out and set aside (see Figure 10).

Remove Blower

Access Panel

Figure 10

EDVI35

Figure 11

14. (EDVI35 only) Remove the blower per

instruction in Figures 12 through 14.

EDVI30

14. (EDVI35 ONLY) When reinstalling the

blower (reverse steps in Figures 12

through 14),

15. To reinstall blower, reverse steps 1-14.

Remove Screws

To remove, tip blower

back, pull it forward,

then tip back upright.

Disconnect wires from terminals & green

ground wire after blower is pulled forward.

Blower

13. (EDVI30 only) Remove the two blower

mounting screws and remove blower per

instructions in Figure 11.

Remove Screws

Blower

Figure 12 - EDVI35

Blower - RH Side View

Ou

tle

t

Rotate blower 45° clock-

wise toward the back,

then pull it forward so that

it is directly below the

blower access opening.

Rotate it so that the outlet

is again pointing upward.

Proceed to instructions in

Figure 14.

Access Opening

Figure 13 - EDVI35

Fr

on

t

Ba

ck

Disconnect wires from terminals on blower (including green

ground wire). Proceed to instructions in Figure 13.

Rotate Blower 90°

counterclockwise,

while lifting blower up

at the same time. Lift

out as shown below.

Fr

on

t

Ba

ck

Figure 14 - EDVI35

Blower Outlet

Front

Back

This manual is related to the following products: