Operation – Lincoln Electric INVERTEC V350-PRO SVM152-A User Manual
Page 16

OPERATION
B-6
B-6
V350-PRO
Auxiliary Power
• 115VAC, 42VAC and 24VAC power is available
from the two 14-pin amphenols on the rear of the
unit. (K1728-2 Construction model of the Invertec
V350-Pro does not have the amphenols) These
supplies are intended to supply power for auxiliary
equipment like wire feeders and the TIG Module.
• 115VAC supply is rated at 2 amps and is protected
by a 2.5 amp breaker located by the amphenol.
• 42 VAC supply is rated at 5.5 amps and is protect-
ed by a 6 amp breaker located by the amphenol.
• 24 VAC supply is rated at 5.5 amps and is protect-
ed by a 6 amp breaker located by the amphenol.
Limitations
• The V350-Pro is not recommended for processes
other than those listed.
• The V350-Pro can only be used with the recom-
mended equipment and options.
Recommended Processes
Properly equipped, the Invertec V350-Pro supports
GMAW, FCAW, SMAW, GTAW and CAC-A
processes for a variety of materials, including mild
steel, stainless steel, cored wires, and aluminum.