Lennox Hearth 775 User Manual

Page 5

background image

5

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Top View / Corner Clearances

* Dimensions with a single asterix are reference dimensions only.

** If the optional warming shelves are installed, a greater alcove width is
required as follows:

CI1500DVF - 44" (1118 mm) min.
CI2500DVF - 52 1/2" (1334 mm) min.

***This includes any projections such as shelves, windowsills, mantels, etc.
above the appliance.

Note: Recommended clearance zone from the front of the appliance to combus-
tibles is 36 inches (914 mm) minimum
.

Floor Protection

When installed directly on carpeting, tile (see Note below) or other combustible material
other than wood fl ooring, the appliance shall be installed on a metal or wood panel extend-
ing the full width and depth of the stove body.

Note: Ceramic tile is non-combustible and does not require a wood or metal panel under
the appliance.

Vent Clearances - All Models

For Horizontal Sections:
Top - 3" (76.2 mm) min.
Sides - 1" (25.4 mm) min.
Bottom - 1" (25.4 mm) min.

For Vertical Sections:
Sides - 1" (25.4 mm) min.

Top View / Rear Wall or Alcove Clearances

Side View / Rear Wall or Alcove Clearances

Clearance To Combustibles

& Alcove Dimensions

CLEARANCES

CI1500DVF

CI2500DVF

A (minimum)

*10” (254 mm)

B (minimum)

*14-1/4” (362 mm)

*17-1/4” (438 mm)

C (minimum)

*15-7/8” (403 mm)

*19” (483 mm)

D (minimum)

4” (102 mm)

4” (102 mm)

E (minimum)

2” (51 mm)

2” (51 mm)

F (minimum)

4” (102 mm)

4” (102 mm)

G (minimum)

0” (0 mm)

0” (0 mm)

H (minimum)

***62” (1575 mm)

***62” (1575 mm)

I (minimum)

**28 1/2” (724 mm)

**34 1/2” (876 mm)

J (MAXIMUM)

48” (1219 mm)

48” (1219 mm)

*10” (254 mm)

Figure 2

CLEARANCES TO COMBUSTIBLE MATERIALS / FLOOR PROTECTION

• The location should also be free of electrical, plumbing or other heating/air conditioning
ducting.
• Due to high temperatures, this appliance should be located out of traffi c and away from
furniture, draperies and not in windy or drafty areas.
• This appliance can be installed in most residential room confi gurations, parallel to a rear
or adjacent wall, or in an alcove that allows for the minimum clearances to combustible
surfaces. Your local building inspector should review your plans prior to installation.
• When installing this appliance, provide adequate clearances for the purposes of servicing
and proper operation.
• As determined through the safety certifi cation of this unit, a minimum clearance to
combustible materials must be maintained around specifi c areas of the gas appliance. (See
Table 5 & Figure 2)

Table 5

H

D

*A

G

J

L E N N O X

*B

D

E

E

I

F

F

*C

At Wall Firestops:
Top - 3" (76.2 mm) min.
Sides - 1" (25.4 mm) min.
Bottom - 1/2" (12.7 mm) min.