beautypg.com

Pipeliner g70m, Welding positions advantage lincoln, Typical applications – Lincoln Electric 2HBG User Manual

Page 15: Shielding gas, Deposit composition, Diameters / packaging, Diffusible hydrogen, Mechanical properties, Conformance, Typical operating procedures

background image

15

Pipeliner

www.lincolnelectric.com

1G

2F

2G

3G ➔

4G

5G ➔

Pipeliner G70M is designed to
deliver outstanding weld properties
for semi-automatic applications.
Robust impacts mean consistently
high CVN values.

PIPELINER G70M

AWS E71T-1MJH8 & E71T-9MJH8 Gas-Shielded Flux-Cored (FCAW-G) Wire Electrode

WELDING POSITIONS

ADVANTAGE LINCOLN

• Impacts are typically in the 60 ft•lbf

@ -20°F (-29°C), as-welded.

• Smooth, spray type arc transfer and

low spatter level.

• Slag system provides for puddle

support, good wetting and bead
shape in all positions.

• Manufactured under a quality

system certified to ISO 9001
requirements.

• Manufactured to actual lot control.

Actual certificates of conformance
are available upon request.

TYPICAL APPLICATIONS

• All position single and multiple pass

wire designed to join pipe up to
X70.

SHIELDING GAS

75-80% Ar / Balance CO2
Flow Rate 40-50 CFH (19-24 l/min.)

DEPOSIT COMPOSITION

-As Required per AWS A5.20-95

%C

%Mn

%P

%S

%Si

%Ni

Requirements
AWS E71T-1MJH8

.18

1.75

.03

.03

.90

.50

AWS E71T-9MJH8

max.

max.

max.

max.

max.

max.

Typical Results
75% Ar / 25% CO2

.05

1.60

.013

.011

.45

.36

DIAMETERS / PACKAGING

Diameter

10 Lb. (4.5 kg)

25 Lb. (11 kg)

in.

(mm)

Plastic Spool

Plastic Spool

Foil Bag

Foil Bag

.045 (1.1)

ED030926

ED030927

NOTE: Pipeliner elec-
trodes are manufactured
under lot control. A
Certificate of Test show-
ing actual deposit chem-
istry and mechanical
properties per AWS
A5.20 is available on
request from the factory
for every lot of electrode.
(Fax 216-383-8386).

DIFFUSIBLE HYDROGEN

- As Required per AWS A5.20-95

(mL/100g

weld deposit)

Requirements
E71T-1MJH8

8

& E71T-9MJH8

Typical Results

4 - 8

75-80% Ar/CO

2

MECHANICAL PROPERTIES

- As Required per AWS A5.20-95

Charpy V-Notch

Yield Strength

Tensile Strength

Elongation

ft•lbf (Joules)

psi (MPa)

psi (MPa)

(%)

@ -40ºF (-40ºC)

Required

58,000 (400)

70,000 (480)

22

20

(27)

AWS E71T-1MJH8

min.

min.

min.

min.

& E71T-9MJH8

Typical Results
75% Ar / 25% CO

2

80,000

89,000

26

78

(106)

(550)

(612)

CONFORMANCE

AWS A5.20-95: E71T-1MJH8

E71T-9MJH8

ASME SFA-5.20: E71T-1MJH8

E71T-9MJH8

TYPICAL OPERATING
PROCEDURES

Diameter

Parameters

.045 in. (1.1mm)

Polarity

DC+

CTWD

(1)

– in. (mm)

3/4 (19)

Wire Weight – lbs/in. (g/m)

.361/1000 (6.45)

Wire Feed Speed – in/min (m/min)

175-525 (4.4-13.3)

Arc Voltage (volts)

23-30

Approx. Current (amps)

130-275

Melt-off Rate – lbs/hr (kg/hr)

3.9-11.9 (1.8-5.4)

Deposition Rate – lbs/hr (kg/hr)

3.2-9.8 (1.4-4.4)

(1)

CTWD (Contact
Tip to Work
Distance).
Subtract 1/4" to
calculate Electrical
Stickout.