beautypg.com

C4t4w, Calculite hid wall wash – Lightolier Calculite HID Wall Wash C4T4W User Manual

Page 2

background image

C4T4W

Calculite HID wall wash

Page 2 of 3

200

400

600

800

30°

60°

30°

Downlight

Wall wash

Side Side

Downlight

Wall wash

Side Side

20W T4 GE Ceramic MH, lumen rating = 1700 LMS., Aromat 20W electronic ballast, CL finish reflector. Report no. 2427FR

Multiple units -

footcandles on wall

2' From wall - 3' on center

1 19.6 18.2 19.6

2 25.8 26.7 25.8

3 27.5 26.7 27.4

4 24.8 23.8 24.8

5 20.2 20.1 20.2

6 16.9 16.8 16.9

7 13.9 13.7 13.9

8 11.8 11.7 11.8

9 10.2 10.1 10.2

10 8.9 8.9 8.9

11 8.1 8.1 8.1

12 7.5 7.5 7.5

13 7.1 7.1 7.1

14 6.9 6.8 6.9

Distance fr

om ceiling in f

eet

3'

Multiple units -

footcandles on wall

3' From wall - 3' on center

1 15.6 9.7 15.6

2 19.2 15.2 19.2

3 18.2 18.5 18.1

4 16.8 16.0 16.8

5 14.3 12.9 14.3

6 11.7 11.1 11.7

7 9.4 9.3 9.4

8 8.0 8.0 8.0

9 6.9 6.8 6.9

10 6.1 6.0 6.1

11 5.5 5.5 5.5

12 5.1 5.1 5.1

13 4.8 4.8 4.8

14 4.7 4.7 4.7

Distance fr

om ceiling in f

eet

3'

Multiple units -

footcandles on wall

3' From wall - 4' on center

1 6.5 6.3 6.5

2 11.5 11.1 11.5

3 12.1 12.6 12.1

4 12.7 12.9 12.7

5 13.0 12.3 13.0

6 11.8 11.4 11.8

7 10.5 10.4 10.5

8 9.3 9.3 9.3

9 8.4 8.3 8.4

10 7.6 7.5 7.6

11 6.9 6.8 6.9

12 6.3 6.3 6.3

13 5.9 5.8 5.9

14 5.6 5.5 5.6

Distance fr

om ceiling in f

eet

4'

39W T4 Philips Ceramic MH, lumen rating = 3300 LMS., Aromat 39W electronic ballast, CL finish reflector. Report no. 2426FR

Multiple units -

footcandles on wall

2' From wall - 3' on center

1 32.2 20.3 32.2

2 34.1 28.4 34.1

3 33.7 31.7 33.7

4 30.8 30.7 30.8

5 26.9 24.9 26.9

6 22.1 21.4 22.1

7 17.8 17.8 17.8

8 15.2 15.3 15.2

9 13.2 13.2 13.2

10 11.6 11.6 11.6

11 10.5 10.5 10.5

12 9.7 9.7 9.7

13 9.2 9.2 9.2

14 8.9 8.9 8.9

Distance fr

om ceiling in f

eet

3'

Multiple units -

footcandles on wall

3' From wall - 3' on center

1 13.6 13.2 13.6

2 23.4 22.5 23.4

3 22.4 22

22.4

4 22.5 22.5 22.5

5

23.5 22.8 23.5

6 22.1 21.6 22.1

7 19.9 19.8 19.9

8 17.8 17.9 17.8

9 16 16

16

10 14.4 14.4 14.4

11 13.2 13

13.2

12 12.1 12

12.1

13 11.2 11.2 11.2

14 10.6 10.6 10.6

Distance fr

om ceiling in f

eet

3'

Multiple units -

footcandles on wall

3' From wall - 4' on center

1 10.2 8.4 10.2

2 18.5 14.8 18.5

3 16.7 15.3 16.7

4 17 15.8 17

5 16.7 17.1 16.7

6 16.3 15.6 16.2

7 14.9 14

14.9

8 13.1 12.7 13.1

9 11.6 11.5 11.6

10 10.3 10.4 10.3

11 9.3 9.4 9.3

12 8.5 8.6 8.5

13 7.9 7.9 7.9

14 7.4 7.5 7.4

Distance fr

om ceiling in f

eet

4'

Lighting data - example

C4T4WCLW illumination on the wall

5' down from the ceiling is 23.5 f.c.

beneath and 22.8 f.c. between fixtures.

3'

23.5 f.c.

23.5 f.c.

5'

3'

22.8 f.c.

375

750

1,125

1,500

60°