Fbp50, 1,400 l, Umen – Lightolier FBP Series Fluorescent Emergency Ballast FBP50 User Manual
Page 2: Inear, Luorescent, Allast

FBP50
1,400 L
UMEN
L
INEAR
F
LUORESCENT
E
M
. B
ALLAST
Page 2 of 2
Philips Lightolier
e: [email protected]
t: (508)
679-8131
w: www.lightolier.com
FBP50 August 28, 2012
Specifications are subject to change without notice.
© Koninklijke Philips Electronics N.V., 2012. All rights reserved.
Job Information
Type:
Ordering Information
Series
FBP50 = 1,400 Lumen Max. Output
Fluorescent Emergency Ballast for One
or Two Lamp Operation
FBP50
LAMP
TYPE
F20T12
F30T12
F40T12
F40T12/U
F48T12
F60T12
F72T12
F96T12
F24T12HO
F36T12HO
F48T12HO
F60T12HO
F72T12HO
F96T12HO
F48T12
F17T8
F25T8
F32T8
F32T8/U
F40T8
F96T8
F27BX
F282D
F382D
F39/36BX
F40/30BX
F50BX/FT55
F96T12HO
F96T12VHO
WATT.
20
30
40
40
40
50
55
75
35
45
60
75
85
95
110
17
25
32
32
40
59
27
28
38
39
40
50-55
95
95
BASE TYPE
G13/Med Bi-Pin
G13/Med Bi-Pin
G13/Med Bi-Pin
G13/Med Bi-Pin
FA8/Single-Pin
FA8/Single-Pin
FA8/Single-Pin
FA8/Single-Pin
R17D/Recessed
R17D/Recessed
R17D/Recessed
R17D/Recessed
R17D/Recessed
R17D/Recessed
R17D/Recessed
G13/Med Bi-Pin
G13/Med Bi-Pin
G13/Med Bi-Pin
G13/Med Bi-Pin
G13/Med Bi-Pin
FA8/Single-Pin
2G11/4-Pin
GR10Q-4/4-Pin
GR10Q-4/4-Pin
2G11/4-Pin
2G11/4-Pin
2G11/4-Pin
R17D/Recessed
R17D/Recessed
NON-EMERGENCY
MAX. LUMEN OUTPUT
1275
2350
2650
3100
2875
3600
4500
5500
1620
2800
5150
4050
6350
8000
6200
1325
2080
2850
2700
3600
5800
1800
2050
2850
2850
3150
4300-4800
8000
8000
NOTES
1) Maximum non-emergency lumen output can vary based on lamp manufacturer, ambient operating temperature,
and ballast manufacturer.
2) Maximum emergency lumen output is based on total output of one or two lamps, and can vary based on lamp
manufacturer and ambient operating temperature.
3) Consult factory for compatibility, operation and performance of lamp types not listed.
Options
EX
1
= Special Input Transformer
(specify voltage and frequency)
DL = Damp Location Listing
Lamp Operation and Performance
Table 1
Accessories (order as a separate item)
CCAPS = Wire Cover Kit for External Mounting
RTS = Remote Test Plate
RTS2 = Remote Test Switch & Pilot Light Kit (includes plate)
EMERGENCY OP.
MAX. LUMEN OUTPUT
1100-1400
1100-1400
1100-1400
1100-1400
1100-1400
1100-1400
1100-1400
1100-1400
1100-1400
1100-1400
1100-1400
1100-1400
1100-1400
1100-1400
1100-1400
1100-1400
1100-1400
1100-1400
1100-1400
1100-1400
1100-1400
1000
1100
1000
1100
1100
1100
1100-1400
1100-1400
EMERGENCY
LAMP OPERATION
One or Two
One or Two
One or Two
One or Two
One or Two
One
One
One
One
One
One
One
One
One
One
One or Two
One or Two
One or Two
One or Two
One
One
Two
One or Two
One or Two
One or Two
One
One or Two
One
One
Note
1) Some option combinations may impact UL listing. Consult factory for specifics.