beautypg.com

Troubleshooting & repair, Caution – Lincoln Electric LN-9 SVM127-A User Manual

Page 76

background image

TROUBLESHOOTING & REPAIR

F-18

F-18

LN-9 Wire Feeder

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

TROUBLESHOOTING GUIDE

Observe Safety Guidelines

detailed in the beginning of this manual.

PROBLEMS
(SYMPTOMS)

POSSIBLE AREAS OF
MISADJUSTMENT(S)

RECOMMENDED
COURSE OF ACTION

METER FUNCTION PROBLEMS

The SET and actual speed meter
readings match within a few IPM,
but both are in error.

1.

Contact your local Lincoln
Authorized Field Service
Facility.

1. Check to make sure the slotted

disc in the tach housing is
secure and aligned.

2. Perform the

Meter Circuit

Accuracy Test.

3. The control board may be faulty.

Replace.

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con-
tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call
216-383-2531 or 1-800-833-9353.

SET speed and actual speed meter
readings do NOT match within a
few IPM. One or both readings
may be erratic.

1.

Contact your local Lincoln
Authorized Field Service
Facility.

1. Check the Volts - Speed meter

selector switch and the associ-
ated wiring. See the Wiring
Diagram.

2. Check the SET - Actual switch

and the associated wiring. See
the Wiring Diagram.

3. Perform the

Meter Circuit

Accuracy Test.