beautypg.com

Theory of operation, Trigger and shutdown circuit – Lincoln Electric LN-9 SVM127-A User Manual

Page 55

background image

TRIGGER AND SHUTDOWN
CIRCUIT

When the gun trigger switch is activated (closed), the
trigger board completes the trigger signal path. This
energizes the CR1 relay located on the power board.
The CR1 relay activates the wire drive motor and the
#2 and #4 circuit, which then activates the Lincoln
welding power source. The CR1 relay may also be
used to energize a gas solenoid.

The normally closed relay located on the voltage board
is in series with the trigger signal. If an out-of-voltage-
range signal or a ground fault condition should occur,
the CR501 (on voltage board) relay contacts would
"open," and the trigger signal path would be interrupt-
ed. This would cause the wire feeder to "shut down"
until the gun trigger is released or the ground fault pro-
tector is reset.

THEORY OF OPERATION

E-3

E-3

LN-9 Wire Feeder

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

NOTE: Unshaded areas of Block Logic Diagram are the subject of discussion.

FIGURE E.3 – TRIGGER AND SHUTDOWN CIRCUIT

INPUT

CONNECTOR

TO

VOLTAGE

BOARD

TO

CONTROL

BOARD

METER

BOARD

VOLTS
SPEED

SWITCH

T1

CIRCUIT

BREAKER

R1

TRIGGER

CONNECTOR

TRIGGER

BOARD

F
U
S
E

T2

WIRE FEED

MOTOR

THERMOSTAT

C

O

N

T

R

O

L

B

O

A
R

D

VOLTAGE

BOARD

P
O

W

E

R

B

O

A

R

D

GROUND

LEAD

PROTECTOR

WIRE

FEED

MOTOR

TACH

BOARD

WIRE
SPEED
CONTROL

VOLTAGE

CONTROL

POLARITY

SWITCH

VOLTAGE SENSING

VOLTAGE CONTROL

POWER SOURCE OUTPUT TRIGGER

(#2 )

S
H

U
T
D
O

W

N

+ 15VDC

+ 15VDC

WIRE SPEED CONTROL

GEAR

BOX

TRIGGER SIGNAL

TRIGGER SIGNAL

R
E
F
E
R
E
N
C
E

V
O

L
T
A
G

E

WORK

ELECTRODE VOLTAGE SENSING

24VAC

28VAC

10VAC