SPECIFICATIONS
Oil
H
ti
Model Number
O23V2/3−70/90
O23V3/4−105/120
O23V5−140/154
Heating
Performance
Low Fire
Input − Btuh (kW)
70,000 (20.5)
105,000 (30.8)
140,000 (41.0)
Performance
Output − Btuh (kW)
58,000 (16.7)
85,000 (24.9)
113,000 (33.1)
High Fire
Input
90,000 (26.4)
119,000 (34.8)
154,000 (45.1)
g
Output
74,000 (21.7)
97,000 (24.9)
125,000 (36.6)
1
A.F.U.E.
83%
81%
81%
Flue Connection Round − in. (mm)
6 (152)
6 (152)
6 (152)
Temperature Rise Range °F (°C)
50 − 80 (28 − 44)
50 − 80 (28 − 44)
55 − 85 (31 − 47)
Oil Burner
Nozzle rating − gph (L/hr) − Low
.50 (1.9)
.65 (2.5)
.85 (3.2)
4
High
4
.65 (2.5)
4
.75 (2.8)
4
1.00 (3.8)
Nozzle spray angle − Low
80
° hollow
80
° solid
80
° solid
4
High
80
° solid
80
° solid
80
° solid
Oil Burner Pump
1 Stage
1 Stage
1 Stage
Oil Burner Pump Pressure − psig (Pa)
100 (690)
140 (965)
140 (965)
Oil Burner Air Inlet Connection (dia.) − in (mm)
4 (102)
4 (102)
4 (102)
Blower
Data
Motor hp (W)
1/2 (373)
1/2 (373)
3/4 (560)
Data
Wheel nom. diameter x width − in. (mm) 10 x 8 (254 x 203)
10 x 10 (254 x 254)
12 x 11 (305 x 280)
Nominal add−on cooling − Tons (kW)
1.5 − 3 (5.3 − 10.6)
2 − 3.5 (7.0 − 12.3)
3 − 5 (10.6 − 17.6)
2
Filter
Number of filters
1
1
3
2
Size of filters − in.
16 x 25 x 1
16 x 25 x 1
16 x 25 x 1
mm
406 x 635 x 25
406 x 635 x 25
406 x 635 x 25
Shipping weight Ċ lbs. (kg) 1 package
225 (102)
225 (102)
275 (125)
Electrical
Characteristics
120V−60hz−1ph
120V−60hz−1ph
120V−60hz−1ph
Maximum overcurrent protection (amps)
15
15
15
Optional Accessories − Must Be Ordered Extra
Half−Height Coil Case
19M11
19M11
19M12
g
Fits uncased C33 coils
B"−width
B"−width
C"−width
Dimensions − in.
5 x 19−1/2 x 21−3/4
5 x 19−1/2 x 21−3/4
5 x 22−1/2 x 22−7/8
mm
127 x 495 x 552
127 x 495 x 552
127 x 572 x 581
Oil Filters
10 micron without mounting bracket
81P89
81P89
81P89
10 micron with mounting bracket
53P92
53P92
53P92
Replacement cartridge − 10 micron, 45 gph
53P93
53P93
53P93
Filter restriction indicator gauge
53P90
53P90
53P90
SignatureStat
t Home Comfort Control
81M27
81M27
81M27
Two Stage Oil Pump
65A44
65A44
65A44
1