Diagrams, Installation & operation manual, Figure 13-1 wiring diagram – Lochinvar 400 User Manual

Page 77: High voltage low voltage 120 vac

background image

Installation & Operation Manual

77

Figure 13-1 Wiring Diagram

13

Diagrams

X1-7

OR

OR

BR

PR

OR

BR

BR

PR

PR

CN2-4

CN2-1

CN1-5

CN1-6

CN1-3

CN1-4

CN1-1

CN1-2

K1

K2

K3

RELAY

BOARD

ON/OFF

SWITCH

JUNCTION

BOX

BK

W

1 2 3 4 5

G

R

R W

3.5A

R

T

W

BK

Y

BL

KB 801

ONLY

BLOWER

-T

HIGH LIMIT SENSOR S1b

OPERATING SENSOR S1a

INLET SENSOR S2

FLUE SENSOR S3a

FLUE SENSOR S3b

INTEGRATED

CONTROL

BK

Y

GAS VALVE
@24VAC

SPARK

ROD

TRANSFORMER

TR2

G

HIGH VOLTAGE SPARK LEAD

CAUTION

FLAME SENSOR

ALARM

CONTACTS

RUN-TIME

CONTACTS

24 VAC LOUVER

RELAY COIL

LOUVER

PROVING SWITCH

GAS PRESSURE

SWITCH

FLOW

SWITCH

TANK

THERMOSTAT

ROOM TSTAT

ZONE CONTROL 3

ROOM TSTAT

ZONE CONTROL 2

ROOM TSTAT

ZONE CONTROL 1

11
12
13
14
15
16
17
18
19
20

SYSTEM

SENSOR

OUTDOOR

SENSOR

TANK

SENSOR

CASCADE

A

B

SHIELD

SHIELD

0-10V

+

-

BMS

IN

0-10V

+

-

SYS PUMP

IN

0-10V

+

-

BLR PUMP

OUT

0-10V

+

-

RATE

OUT

MODBUS

OPTION

A

B

SHIELD

SHIELD

LOW

WATER

CUT-OFF

24 VAC

COM

P/BK

Y

W/R

1
2
3
4
5
6
7
8
9

10

21
22
23
24
25
26
27
28
29
30
31
32

33
34
35
36
37
38
39
40
41
42
43
44

CN7-1
CN7-2
CN7-3
CN7-4

CN5-1
CN5-8
CN5-2
CN5-9
CN5-3

CN5-10
CN5-11

CN5-4
CN5-5

CN5-14
CN5-12

CN5-6

CN5-13

CN5-7

X1-3

X1-4

X1-2

X1-6
X1-5

X1-8

X1-1

X5-7

X5-16

X5-8

X5-15

X5-9

X5-1

X5-2

X5-10

X5-11

X5-4

X5-12

X5-6

X5-5

X5-13

X5-14

X2-2

X2-1

BK

AIR PRESSURE
SWITCH

BLOCKED DRAIN
SWITCH

O

P

O/BK

Notes:
1. All wiring must be installed in accordance with: local, state, provincial and national code requirements per either N.E.C. in USA or C.S.A. in Canada.
2. If any original equipment wire as supplied with the appliance must be replaced, it must be replaced with wire having same wire gauge (AWG) and rated for a
minimum of 105°C. Exceptions: Replacement high vo ltage spark lead and ribbon cables must be purchased from the factory. Use of a non-approved spark lead
or ribbon cables can lead to operational problems which could result in non-repairable damage to the integrated controller or other components.
3. Actual connector block locations may vary from those shown on diagrams. Refer to actual components for proper connector block locations when using
diagrams to troubleshoot unit.

WIRING DIAGRAM

LBL20116 REV B

BOX DEPICTS

OPTIONAL ITEMS

CN2-2

CN2-3

DHW
PUMP

BOILER
PUMP

SYSTEM
PUMP

120V
SUPPLY

L

N

GND

X4-7

X4-14

X4-6

X4-13

X4-5

X4-12
X4-11

X4-4
X4-3
X4-8

X4-10

X4-2
X4-9
X4-1

L

N

BK
BK
BK
BK

BK
BK
BK
BK
BK

BK
BK
BK
BK

CONNECTION BOARD

CN6

X6

X-7

BOX DEPICTS

DUAL SENSOR

SINGLE HOUSING

MODBUS BOARD

MTR-01

CN8

-1

CN8

-2

CN8

-3

X6

-3

X6

-2

X6

-1

X6

-4

X9-1
X9-2
X9-3
X9-4

X4-1
X4-2
X4-3
X4-4

X5-1
X5-2

X1-1
X1-2
X1-3

BK

W

G

R BL G

-T

-T

-T

-T

SHIELD

GROUNDING

JUMPER

O

GY

G

R/BK

W/BK

GY

PR

1 2

G

3

BELL

J

U

M

PER

ALARM

B

E

LL

SI

L

E

NCI

N

G SW

IT

CH

HIGH VOLTAGE

LOW VOLTAGE
120 VAC