Failure and error messages – LaCie FIREWIRE 800/400 User Manual
Page 39

LaCie Biggest Quadra
User Manual
page
Using the Biggest Quadra
5.2.3. Failure and Error Messages
■
These messages will be displayed in the event of a
RAID or disk failure, or an error during a process.
RAID Failure Messages
LCD Display
Message
Message Cleared When...
RAID Fail
code: 0
The RAID array failed. There are not
enough disks for the RAID array to
operate.
A disk is re-installed
❖
RAID Fail
code: 1 <---->
The RAID array failed. The sequence
of the disks in the array is incorrect.
The current sequence is displayed
within the “<---->” space.
The original disk sequence is
restored
❖
RAID Fail
code: 2
The RAID array failed but all original
disks are existing after restarting the
unit.
The RAID array is recreated.
❖
Disk Failure Message
LCD Display
Message
Message Cleared When...
DISK x Fail
Disk “x” failed.
The failed disk is replaced
❖
Fan Failure Message
LCD Display
Message
Message Cleared When...
FAN Fail
xxxx rpm
Fan failure. xxxx rpm = the current
speed of the fan
The failed fan is repaired or replaced
❖