beautypg.com

Setting the raid level – LaCie FIREWIRE 800/400 User Manual

Page 22

background image

LaCie Biggest Quadra

User Manual

page

Setting Up the Biggest Quadra

4.1. Setting the RAID Level

The LaCie Biggest Quadra is pre-configured at RAID

level 5, but it may be re-configured. The RAID level is set

using the RAID Level Switch Selectors on the rear panel of

the LaCie Biggest Quadra. The RAID level selectors consist

of two switches, with four possible switch position combina-

tions: RAID 0, 0 + 1, 5 and 5 + Hot Spare.

CAUTION:

The LaCie Biggest Quadra must

be powered off to change the RAID level.

ImpOrTANT INfO:

In the event that the

RAID level does not correspond to both the disk

settings and the RAID Level Switch Selectors, the

LCD will display the following two alternating

messages:

1. “RAID level”

“Unmatched”

2. “Current: Rx” (i.e. the current RAID level set-

tings of the installed disks)

“Original: Rx” (i.e. the RAID level settings on

the RAID Level Switch Selectors)

Example:

The RAID Level Switch Selectors are posi-

tioned to indicate a RAID 0 setting, but the

disks were set earlier as a RAID 5 array, the

LCD will display the following two alternating

messages:

1. “RAID Level”

“Unmatched”

2. “Current: R5”

“Original: R0”

In this situation, the array will not function.

There are two options:

1. Shut down the LaCie Biggest Quadra and

re-position the RAID Level Switch Selectors

to the previous RAID setting, in this case,

RAID 5.

2. Re-insert the four drives, and re-create the

array as a RAID 0 array. If there is any data on

the disks, it will be lost during the initializa-

tion.

CAUTION:

If there is data on the array, chang-

ing the RAID level may lead to the loss of all of

the data on the array.