beautypg.com

Raid 5, Raid 5 + hot spare – LaCie FIREWIRE 800/400 User Manual

Page 23

background image

LaCie Biggest Quadra

User Manual

page

Setting Up the Biggest Quadra

This is the default setting of the LaCie Biggest

Quadra. Follow these steps to set the RAID level at

RAID 5.

Power off the LaCie Biggest Quadra.
Move switch 1 and 2 of the RAID Level Switch Se-

lectors to the

OFF

position.

1.
2.

4.1.1. RAID 5

CAUTION:

In a RAID 5 array, in the event

that a disk needs to be replaced, always replace the

failed disk with the LaCie Biggest Quadra’s power

on. Do not turn the LaCie Biggest Quadra’s power

off; doing so may lead to the loss of the data on

the array.

ImpOrTANT INfO:

In a RAID 5 + Hot

Spare array, the disk in the top drive bay is desig-

nated as the Hot Spare (the default setting), and

the Disk Status Indicator will light in amber to

indicate this configuration.

Power off the LaCie Biggest Quadra.
Move switch 1 of the RAID Level Switch Selectors

to the

OFF

position. Move switch 2 of the RAID

Level Switch Selectors to the

ON

position.

1.
2.

4.1.2. RAID 5 + Hot Spare

TeChNICAl NOTe:

In the initial configura-

tion of a RAID 5 + Hot Spare array, the top drive

bay (Drive Bay 1) is the default Hot Spare (the Disk

Status Indicator will be amber). In the event that a

disk fails, the Hot Spare position will change.

For example, if the disk in Drive Bay 3 fails, then

the Hot Spare disk in Drive Bay 1 will be re-built

and will no longer be the Hot Spare. Instead,

when you place a new disk in Drive Bay 3, it will

become the new Hot Spare, and will be indicated

by the amber Disk Status Indicator.

Fig. 4.1.1