beautypg.com

Product features – Linear J-S User Manual

Page 3

background image

The purpose of this booklet is to provide assembly,

installation and operation information concerning Model J-S

& H-S Commercial Vehicular Garage Door Operators and

related Accessory Products.

NOTICE

IT IS IMPORTANT THAT THIS INSTRUCTION

MANUAL BE READ AND UNDERSTOOD

COMPLETELY BEFORE INSTALLATION OR

OPERATION IS ATTEMPTED. IT IS INTENDED

THAT THE INSTALLATION OF THIS UNIT WILL BE

DONE ONLY BY PERSONS TRAINED AND

QUALIFIED IN THE INSTALLATION, ADJUSTMENT

AND SERVICE OF COMMERCIAL OVERHEAD

DOORS AND DOOR OPERATORS AND BY

QUALIFIED ELECTRICIANS.

NOTICE

THE IMPORTANT SAFEGUARDS AND

INSTRUCTIONS IN THIS MANUAL CANNOT COVER

ALL POSSIBLE CONDITIONS AND SITUATIONS

WHICH MAY OCCUR DURING ITS USE. IT MUST

BE UNDERSTOOD THAT COMMON SENSE AND

CAUTION MUST BE EXERCISED BY THE PERSON

(S) INSTAL- LING, MAINTAINING AND OPERATING

THE EQUIPMENT DESCRIBED HEREIN. DO NOT

USE THIS EQUIPMENT FOR ANY OTHER THAN ITS

INTENDED PURPOSE - OPERATING OVERHEAD

COMMERCIAL VEHICULAR GARAGE DOORS.

STANDARD FEATURES:

Solid State Controls: The openers employ solid state technology

with advanced standard features to provide for a complete

commercial door operating system.

Switch Selectable Operating Modes: Six distinct base operation

modes can be selected by resetting the switches on the motor

control board: a standard Open, Close, Stop (B2, momentary

button push); three constant pressure modes (C2, D1, and E2); two

Timer to Close modes (T and TS). See page 15 for complete

description of the modes.

Switch Selectable Characteristic Modes: Five different

operating characteristics can be activated and/or modified through

the switches on the motor control board: Delay On Reverse, Close

Limit Delay, Mid Stop Travel, Timer to Close, Maximum Run

Timer.

Limit Switches: Driven limit switches, easily adjusted over a

wide range. The motor may be removed without affecting the

limit switch adjustments

Manual Release: Permits manual operation of the door in the

event of a power failure. The Model H-S is equipped with a chain

hoist to aid in manual operation.

Control Circuit: Standard three button open, close and stop. 5

Volts DC.

Connections For Auxiliary Entrapment Protection Devices:

For the ultimate in protection, terminals are provided to connect a

Linear Corp. Photo-Beam System that consists of an emitter, Part

No. 217792 and detector, Part No. 217800. This device when

connected is a monitored photo-beam system. Additional

connection terminals for a Normally Open and Normally

Closed reversing devices such as a reversing door edge or a

three wire photo-beam are provided.

Constant Contact To Close: Standard operating mode. The

operator can be converted to Momentary Contact To Close

when the photo-beam as described above or one of the Miller

Edge family of Door Edge devices as described on this page

is properly installed on the door and connected to the

operator. See Page 10 for the entrapment protection

installation guide.

MODEL J-S & H-S OPERATOR APPLICATIONS:

Jackshaft operators are intended for commercial and industrial use
to raise or lower sectional overhead doors by chain coupling or
direct coupling to the door shaft. Jackshaft operators are suitable
where all or part of the door remains in a vertical position when
fully open such as doors with at least 18 inches of lift clearance or
full vertical lift doors. Jackshaft operators may also be used with
roll up service doors and grills when appropriately modified at the
factory to obtain the correct speeds.
A jackhaft operator DOES NOT LOCK THE DOOR IN
ITS CLOSED POSITION.
However, because the cross-
header shaft is prevented by the operator from turning, the
torsion springs provide no assistance in lifting the door
should an attempt be made to raise it manually.

The J & H Series jackshaft operators are used in the
following applications:

-

Continuous Duty, Medium Cycle Commercial
installations only

-

Indoor Use Only

-

Up to 24 foot high doors with a maximum area of 480

square feet for 3/4 HP, 280 square feet for 1/2 HP and

200 square feet for 1/3 HP - maximum area slightly

higher for lighter doors - consult factory

-

To operate in Momentary Contact To Close mode and

comply with the UL325 Entrapment Protection requirements
effective Aug. 29, 2010, the door system must include one of
the following (a, b, or c):
(a) Linear Corp. Photo-Beam System that consists of an
emitter, Part No. 217792 and detector, Part No. 217800 for
doors as described above up to 30 FT wide. See Page 10.
(b) Any Miller Edge ME, MT/MU, and CPT family of edges,
with suffix T2, must be connected to the SM-102 Edge
Module, Recognized by UL as per UL325 2010 on 08-29-
2010 for door as described above. See Page 10.
(c) A Vitector Fraba OSE 2-wire Photosystem as Recognized
by UL as per UL325 2010 on 08-29-2010 for door as
described above. See Page 10.

- The manufacturer of this operator strongly recommends

installation of one of the entrapment protection device above

and states that one is REQUIRED where any automatic,

remote or manual control is used to activate the door.

OPTIONAL FEATURES:

Digital Radio Controls: Open, Close and Stop operation.

Radio units are available to control up to 27 doors from one

transmitter

Keyless Entry System: Connection terminals provided for

hard wired or wireless keyless entry systems.

PRODUCT FEATURES