Setup modes, Operation & adjustment instructions – Linear J-S User Manual
Page 17

Mid-Stop: Activation stops an opening door; momentary contact 
of open button at mid stop will restart door to full open 
position; if door is moving open, constant pressure on open 
button will bypass mid-stop. 
Auto Close Timer: N/A 
TS Operation
Open Button: Momentary activation; open override of closing 
door. 
Close Button: Momentary activation. 
Stop Button: Momentary activation; stops open, close or reverse 
action. 
Single Button: Momentary activation to open; open override of 
closing door, closes door from mid-stop or open limit. 
EP Reverse (Photo Input): Momentary activation will reverse a 
closing door, reverse to full open (ignores mid-stop) unless 
stopped by stop pushbutton input. 
Mid-Stop: Activation stops an opening door; momentary contact 
of open button at mid stop will restart door to full open 
position; if door is moving open, constant pressure on open 
button will bypass mid-stop. 
Auto Close Timer: Closes door from mid-stop or open limit 
after pre-set time. Stop will deactivate the auto close timer. 
Open will reactivate the auto close timer or reset the auto close 
timer when the door is at the mid-stop or open limit. Single 
button will reset the auto close timer from the mid-stop or open 
limit. Reverse will reactivate the auto close timer or reset the 
auto close timer when the door is at the mid-stop or open limit. 
T Operation, Dip-Switch Setting
Open Button: Momentary activation; open override of closing 
door. 
Close Button: Momentary activation. 
Stop Button: Momentary activation; stops open, close or reverse 
action. 
Single Button: Momentary activation to open; open override of 
closing door, closes door from mid-stop or open limit. 
EP Reverse (Photo Input): Momentary activation will reverse a 
closing door, reverse to full open (ignores mid-stop) unless 
stopped by stop pushbutton input. 
Mid-Stop: Activation stops an opening door; momentary contact 
of open button at mid stop will restart door to full open 
position; if door is moving open, constant pressure on open 
button will bypass mid-stop. 
Auto Close Timer: Closes door from mid-stop or open limit 
after pre-set time. Stop will deactivate the auto close timer. 
Open will reactivate the auto close timer or reset the auto close 
timer when the door is at the open limit. Single button will reset 
the auto close timer from the mid-stop or open limit. Reverse 
deactivates the auto close timer if the door is closing. Reverse 
will reset the auto close timer at the mid-stop or open limit if 
the auto close timer has not been previously deactivated. 
SETUP MODES
Setup Modes
Various operating characteristics can be modified via the setup 
modes. The operator is moved to the close limit position and 
the on-board dip switches (see Figure 14, page 15) are 
TEMPORARILY
set according to the table at right to enter a
Setup Mode. The on board OPEN and STOP buttons are used 
to modify the characteristic. Once set, the values are stored in 
non-volatile memory. 
These values are set to factory defaults that should be 
satisfactory for many applications. All values as described here 
can be reset to the factory defaults as follows: 
Remove 24 VAC power from the control board.
Press and hold the on-board stop button.
Re-apply 24 VAC while holding the on-board stop button.
After completing the procedure to modify the operating
characteristic the switches must be returned to the originally set 
Operating Mode setting (see section previous). 
Delay on Reverse Setup
To help prevent stress on the door components, this feature
allows for a delay time between the door stopping and reversing 
when a command to reverse is received as the door is closing. 
The factory default time is 0.75 seconds; the minimum time is 
0.4 seconds; the maximum time is 2 seconds. 
After moving the door to the close position and temporarily
setting the switches to the appropriate settings in the table, 
pressing STOP will reset the time to the minimum setting. 
Every time OPEN is pressed, 200 mS is added to the time (up to
the maximum).
Changing the dip-switch setting to any other setting will save
the new time. Return the dip switches to the originally set 
Operating Mode setting (see section previous). 
Close Limit Delay Setup
To provide for irregularities in the floor, this feature allows for
the door to continue to travel down after the Reverse Cutout 
Limit is activated. The factory default time is 0.32 seconds; the 
minimum time is 0.12 seconds; the maximum time is 0.66 
seconds. 
After moving the door to the close position and temporarily
setting the switches to the appropriate settings in the table, 
pressing STOP will reset the time to the minimum setting. 
Every time OPEN is pressed, 0.02 seconds are added to the time
(up to the maximum).
Changing the dip-switch setting to any other setting will save
the new time. Return the dip switches to the originally set 
Operating Mode setting (see section previous). 
Setup Mode
Switch 1 Switch 2 Switch 3 Switch 4
Delay on Reverse
ON
ON
ON
ON
Close Limit Delay
OFF
ON
ON
ON
Mid-Stop Limit
ON
OFF
ON
ON
Auto Close Timer
OFF
OFF
ON
ON
Maximum Run Time
OFF
ON
OFF
ON
OPERATION & ADJUSTMENT INSTRUCTIONS
17