beautypg.com

Reversed supplies – Kohler Discovery User Manual

Page 21

background image

21

Reversed Supplies

The Discovery Dual Control is supplied with inlet connections Hot-Left, Cold-Right
and Top-Outlet as standard. If the hot and cold water supply pipes have been reversed
during installation the following procedure must be performed.
Note! Refer to illustrations in section: ‘Installation, Control Assembly’.

‘O’ Key

1.

Isolate the hot and cold water supplies.

2.

Pull off the temperature knob.

3.

Unclip and remove the concealing
plate.
Note! Use a screwdriver in the slot at
the bottom of the concealing plate to
lever off.

4.

Fit the ‘O’ Key (supplied) onto the
cartridge nut and turn anticlockwise.
Unscrew and pull the cartridge clear
from the body.
Note! Depending on the finished wall
thickness it may be necessary to
remove the backplate.

5.

Rotate the cartridge 180°.

6.

Make sure that the two cartridge side
seals are fitted and carefully push into
the cartridge body.
Important! Make sure that the
cartridge side seals do not extrude
from the body when pushing the
cartridge in. Damage to these seals
may result in incorrect operation.

7.

Position the cartridge lugs into the
body slots and tighten the nut by
turning the ‘O’ Key clockwise.

8.

Restore the hot and cold water
supplies and check for leaks.

9.

Refer to section: ‘Installation, Control
Assembly’
and follow instructions 3
to 9.